🌍 🌐 English
Protective Coatings

KingCoat PE300®

Two component solvent based coal tar epoxy resin coating system.

SpecWorld has the Spec Pack, CSI specification and drawings for registered specifiers.

Tensile strength ASTM D412
> 2.0 MPa @ 7 days
Mixed density
1.50 ± 0.05 g/cm³
Solid content
94 ± 2%

Overview

KingCoat PE300 is a two component amine cured coal tar epoxy. The product has excellent chemical resistance properties which makes it particularly suitable for sewage treatment plants and for aggressive environments. KIngCoat is suitable for use on concrete and steel surfaces.

Where to use

KingCoat PE300 is designed for use in applications such as:

Sewage treatment plants.

Protection of concrete and steel structures submerged in sea water or exposed to tidal or splash zones.

Lining of manholes, pipes, jetties, piers, ducting and foundations waterproofing.

Why use it

  • Excellent adhesion to concrete and steel surfaces.
  • Cost effective; does not require primer.
  • Suitable for use as a waterproof coating.
  • High chemical resistance.
  • Does not support bacterial growth.
  • High abrasion resistance.
  • Can be applied to green concrete.
  • Can be applied at 350 micron thickness per coat.

Technical properties

ColourBlack
Mixed density1.50 ± 0.05 g/cm³
Solid content94 ± 2%
Volume solid90 ± 2%
Pot life3 - 4 hr @ 25°C
1 - 2 hr @ 35°C
Full cureAfter 7 days @ 25°C
Over- coating time1 day @ 25°C
Tensile strengthASTM D412> 2.0 MPa @ 7 days
Water absorptionASTM D570< 0.08%
Service temperature−10 to 55°C
VOCASTM D2369< 110 g/ltr

Standards and approvals

KingCoat PE300 complies with:

  • The chemical resistance requirements when tested in accordance with ASTM D1308.
  • BS 5493 reference to KF3 B (Two-pack chemical- resistant finishes, modified epoxy coal tar).

How to use

Method of use

Substrate Preparation

Concrete surfaces

The Substrate should be sound, clean and free from

contamination. Surface Laitance should be removed by grit blasting or water jetting. All blow holes should be filled with epoxy paste such as KingRep EP10.

Steel surfaces

All surfaces should be grit blasted to reach a bright finish meeting the requirement of Swedish Standard SA 2 1/2.

Mixing

To ensure proper mixing, a mechanically powered mixer or drill fitted with suitable paddle should be used. Stir the content of each component separately to disperse any settlement.

Add the entire content of the hardener to the base and mix for 3 minutes and until uniform colour and consistency are achieved.

Application

KingCoat PE300 can be applied by brush, roller or airless spray machine. The first coat should be applied to obtain a continuous uniform coating. The second coat should be applied within the over coating time to achieve the maximum adhesion between coats.

Cleaning

All tools shall be cleaned immediately after application using KINGKRETE Solvent. Hardened materials must be cleaned mechanically.

Limitations and notes

  • The area where KingCoat PE300 is going to be applied must be well ventilated for at least 24 hours, and must not have high relative humidity or any presence of running water.
  • KingCoat PE300 must not be applied over other coats, but only over itself within the recoatable time.
  • Application of KingCoat PE300 should not be done at low temperatures (below 8°C).
  • KingCoat PE300 especially when the coat is still not fully cured, (7 days). However, this colour change does not affect the performance of the coating.

Coverage, packaging and storage

Coverage

0.54 kg/m²/coat.

Two coats should be applied to achieve 700 microns dry film thickness.

Packaging

KingCoat PE300 is available in 25 kg packs.

Storage

Shelf life is 1 year when stored under cover, out of direct sunlight and protected from extremes of temperature. Failure to comply with the recommended storage conditions may result in premature deterioration of the product or packaging. For specific storage advice consult KingKrete's Technical Services Department.

Chemical Resistance after full cureASTM D1308 (after 7 days immersion in the below chemicals)
Organic Acids
Oleic Acid sat.R
Vinegar 10%SS
Inorganic Bases
Sodium Hydroxide 50%R
Ammonia Solution 10%R
Potassium Hydroxide 50%R
Aqueous Solutions
Sodium Chloride satR
Tap waterR
Chlorinated waterR
Dead sea waterR
Solvents
White spiritR
XyleneR
TolueneR
Oils & Fuels
Benzyl alcoholSS
Brake fluidR
Engine oilR
DieselR
KeroseneR
Detergents & SoapsR
Inorganic Acids
Sulphuric Acid 40%R
Nitric Acid 10%R

R: Resistant
RS: Resistant with slight discoloration
SS: Slight softining

Health and safety

As with all chemical products, care should be taken during use and storage to avoid contact with eyes, mouth, skin and foodstuffs. Treat splashes to eyes and skin immediately. If accidentally ingested, seek medical attention. Reseal containers after use. Use in well ventilated areas and avoid inhalation.

Request the safety data sheet