KingCoat EP500HR®
Two component heat resistant epoxy modified cementitious coating.
SpecWorld has the Spec Pack, CSI specification and drawings for registered specifiers.
- Pot life
- 60 min @ 25°C
- Mixed density
- 1.6 ± 0.05 g/cm³
- Solids by weight
- 100%
Overview
KingCoat EP500HR is a solvent free, heat resistant epoxy modified cementitious coating for the protection of concrete, mortar and stone surfaces as well as steel.
Where to use
KingCoat EP500HR is designed for applications such as:
- Heavy duty protective coating for concrete surfaces.
- Protection of concrete sea water channels.
- Water treatment plants.
- Boiling water tanks and water stations.
- Desalination plants.
Why use it
- Can be applied without primer.
- Mold resistant.
- Solvent free.
- High build.
- Abrasion resistant.
- Corrosion resistant.
- Resist thermal shock and freeze-thaw cycles.
- Withstands temperatures up to 130°C.
Technical properties
Values @ 25°C
| Colour | Grey |
|---|---|
| Solids by weight | 100% |
| Mixed density | 1.6 ± 0.05 g/cm³ |
| Pot life | 60 min @ 25°C |
| Touch dry | 6 - 8 hr |
| Re-coatable | 8 - 20 hr |
| Full cure | 7 days |
| Bond strengthASTM D4541-85 | 3.5 MPa (concrete failure) |
| Bond strength after 200 hours water boilASTM D4541-85 | 2 MPa (concrete failure) |
| Water absorptionASTM D570 | < 0.1% |
| Physical effects after 600 hours water boil | No cracking, chalking, softening, blistering or debonding |
Standards and approvals
KingFLoor EP25 complies with BS 476, Part 7: 1987, Class 1 Spread of Flame.
How to use
Surface preparation
Concrete surfaces
Surface to be coated should be sound and free from oil,
grease, mold and fungus, and any loose materials.
Steel surfaces
Steel surfaces should be grit blasted to reach a bright finish meeting the SA21/2 standard. KingCoat EP500HR should be applied as soon as possible after blasting to avoid rust forming.
Mixing
Base and hardener components should be stirred separately. Add the contents of the hardener container to the base container and mix using slow speed mixer or a slow speed drill fitted with suitable paddles. Mixing should continue for 3 minutes or until a homogeneous mix is obtained.
Application
Two coats of KingCoat EP500HR should be applied. The product can be applied using brush, roller and can be spray applied. First coat should be applied uniformly onto the surface at 200 microns thickness.
The second coat should be applied similarly to the first coat between 8 hours and 20 hours (@ 25°C) after applying the first coat.
For exposed areas, it is recommended that KingCoat EP500HR is covered by a polyurethane protective coating from KingCoat range of products.
Cleaning
All tools should be cleaned immediately after application using KINGKRETE Solvent. Hardened materials must be cleaned mechanically.
Coverage, packaging and storage
Coverage
Approximately 1 kg/3 m² per coat. Two coats should be applied to achieve 400 microns dry film thickness.
Packaging
KingCoat EP500HR is available in 5 kg packs.
Storage
Shelf life is 1 year when stored under cover, out of direct sunlight and protected from extremes of temperature. Failure to comply with the recommended storage conditions may result in premature deterioration of the product or packaging. For specific storage advice consult KingKrete's Technical Services Department.
| Occassional Spillage. Chemical Resistance after full cure (7 days @ 25°C), ASTM D1308 (Spot - test @ 1 hr) | |
|---|---|
| Organic acids | |
| Oleic Acid sat. | R |
| Citric Acid 25% | R |
| Vinegar 5% | R |
| Inorganic bases | |
| Sodium Hydroxide 50% | R |
| Ammonia Solution 10% | R |
| Potassium Hydroxide 50% | R |
| Aqueous solutions | |
| Sugar Solution sat. | R |
| Sodium Chloride sat | R |
| Tap water | R |
| Distilled water | R |
| Chlorinated water | R |
| Dead sea water | R |
| Urea Solution 80% | R |
| Oils & Fuels | |
| Benzyl alcohol | SS |
| Brake fluid | R |
| Engine oil | R |
| Diesel | R |
| Kerosene | R |
| Detergents & Soaps | R |
| Inorganic acids | |
| Sulphuric Acid 25% | R |
| Phosphoric Acid 20% | R |
| Hydrochloric Acid 32% | RS |
| Nitric Acid 10% | R |
R: Resistant
RS: Resistant with slight discoloration
SS: Slight softining
Health and safety
As with all chemical products, care should be taken during use and storage to avoid contact with eyes, mouth, skin and foodstuffs. Treat splashes to eyes and skin immediately. If accidentally ingested, seek medical attention. Reseal containers after use. Use in well ventilated areas and avoid inhalation.