🌍 🌐 English
Protective Coatings

KingCoat EN100®

High performance chemical resistant epoxy novolac lining.

SpecWorld has the Spec Pack, CSI specification and drawings for registered specifiers.

Compressive strength BS 6319, Part 2
> 50 MPa
Flexural strength BS 6319, Part 3
> 20 MPa
Tensile strength ASTM C580
> 11 MPa
Hardness
85 ± 5 shore D

Overview

KingCoat EN100 is a two-component seamless epoxy novolac coating designed for areas where excellent wear and chemical resistance is required. KingCoat EN100 is suitable for use on concrete and steel surfaces. The material may be used with or without antislip aggregates and can also can be laminated with glass fibre cloth to achieve a high build, chemical resistant lining.

Where to use

KingCoat EN100 is designed for use in applications, such as:

  • Chemical plants.
  • Sewage treatment plants.
  • Pharmaceutics industry.
  • Petroleum refineries.
  • Storage areas.
  • Loading docks.
  • Food processing areas.

Why use it

  • Excellent chemical resistance.
  • Superior adhesion to concrete and mild steel.
  • High wear resistance.
  • Able to withstand exposure to chemicals with pH ranging from 1 – 14 @ 25°C.
  • Solvent free, 100% solids.
  • Easy and fast application.

Technical properties

FinishGloss
ColourGrey
Solid content100%
Specific gravity1.3 ± 0.05 g/cm³
Full cure7 days @ 25°C
Tack free time8 hr @ 25°C
Pot life45 min @ 25°C
20 min @ 35°C
Flexural strengthBS 6319, Part 3> 20 MPa
Flexural strengthASTM C580> 27 MPa
Over-coating time< 18 hr @ 23°C
< 12 hr @ 35°C
Tensile strengthASTM C580> 11 MPa
Tensile strengthASTM D638> 20 MPa
Compressive strengthBS 6319, Part 2> 50 MPa
Compressive strengthASTM C579> 55 MPa
Bond strengthASTM D4541> 2 MPa
(Concrete failure)
Hardness85 ± 5 shore D
Water absorptionASTM D570< 0.2%
Taber abrasion
resistanceASTM D4060, weight
loss
CS17 wheel, 1000 g,
1000 cycle
CS10 wheel, 1000 g
< 75 mg
< 0.5 mg/cycle
VOCASTM D2369< 10 g/ltr
(complies with LEED)

How to use

Method of use

Substrate Preparation

Concrete surfaces

The Substrate should be sound, clean and free from

contamination. Surface Laitance should be removed by grit blasting or water jetting. All exposed blow holes should be filled with epoxy paste using KingRep EP10

Steel surfaces

All surfaces should be grit blasted to reach a bright finish meeting the requirement of Swedish Standard SA 2 1/2.

Priming

KingCoat EN100 is designed to be used without a primer. However, for highly porous substrates, KingFloor Primer S is recommended.

Mixing

To ensure proper mixing, a mechanically powered mixer or drill fitted with a suitable paddle should be used. Stir the content of each component separately to disperse any settlement.

Add the entire content of the hardener to the base and mix for 3 minutes and until a uniform colour and consistency are achieved.

Application

Coating Finish

KingCoat EN100 can be applied by stiff nylon brush; short nap roller and airless spray machine. The first coat should be applied to obtain a continuous uniform coating. The second coat should be applied within the over coating time to achieve the maximum adhesion between the two coats.

Antislip Finish

The base coat should be applied at a minimum film thickness of 250 microns and then fully blinded with the chosen Antislip Aggregate. Once the base coat has reached initial cure, all excess aggregates should be removed before a further application of KingCoat EN100 top coat.

The top coat should be applied at a minimum film thickness of 400 micron to 750 microns depending on Antislip Aggregate size used.

Use with Glass fibre reinforcement

To increase the thickness of the system or where necessary to bridge fine cracks in the substrate, the glass fibre matt is recommended as reinforcement. Apply one coat at a wet film thickness of 250 microns and while still wet, lay the fibre glass matt directly onto the wet layer and press firmly into the first coat. Wet out mat with additional mixed KingCoat EN100 until mat is saturated. Use a ribbed roller to remove air from the mat allow reinforcement to cure.

Coverage, packaging and storage

Coverage

Standard Coverage

KingFloor Primer S: 5 m²/kg

KingCoat EN100 (base coat): 0.33 kg/m². KingCoat EN100 (top coat): 0.33 kg/m².

Antislip Coverage

KingFloor Primer S: 5 m²/kg.

KingCoat EN100 (base coat): 0.33 kg/m².

Antislip aggregate #2: 0.35 – 0.75 kg/m².

KingCoat EN100 (top coat): 0.50 kg/m². Approximate system thickness: 1.5 mm

CHEMICAL RESISTANCE
KingCoat EN100 is resistant to the spillage and splash of the following chemicalsASTM D1308 @ 24 hours
Acetic Acid 10%Boric Acid 1%
Citric Acid 50%Fatty acids
Fumaric Acid 0.5%Hydrofluoric Acid 25%
Nicotinic Acid 2%Lactic Acid 20%*
Phosphoric Acid 10%Nitric Acid 10%
Tartaric Acid 50%
Phosphoric Acid 55%
Ammonium Hydroxide 30%
Potassium Hydroxide 50%Sodium Hydroxide 50%
Gasoline (Car Fuel)Jet fuel
KeroseneDiesel fuel
SkydrolBrake fluid
Car oilCrude oil
BenzeneCarbon Tetrachloride
HexaneMineral Spirit
TolueneXylene
Methyl Isobutyl KetoneEthanol
IsopropanolBenzoyl Chloride
Diethanolamine 88%Ethylene Glycol
Formaldehyde 37%Hexamine 25%
Hydrazine 35%Propylene Glycol
Magnesium SulphatePotassium Sulphate
Ammonium Ferrous
Sulphate
Ferrous Sulphate
Aluminum Ammonium
Sulphate
Sodium Disulphate
Sodium BenzoateSodium Thiocyanate-an-
hydrous
Ammonium ChlorideAmmonium Acetate
Ammonium ThiocyanateZinc Acetate
Potassium ChromatePotassium Sodium Tartrate
Vegetable OilsSea water
Hydrogen PeroxideBrine 10%

*Resists with slight discoloration.

Packaging

KingCoat EN100 is available in 5 kg packs.

Storage

Shelf life is 1 year when stored under cover, out of direct sunlight and protected from extremes of temperature. Failure to comply with the recommended storage conditions may result in premature deterioration of the product or packaging. For specific storage advice consult KingKrete's Technical Services Department.

CHEMICAL RESISTANCE
Based on test method ASTM D1308 after 7 days immersion, KingCoat EN100 resists the following chemicals with some discoloration
Acetic Acid 10%Phosphoric Acid 10%
Lactic Acid 20%Nitric Acids 10%
Sulphuric Acid 25%Hydrochloric Acid 10%

Health and safety

As with all chemical products, care should be taken during use and storage to avoid contact with eyes, mouth, skin and foodstuffs. Treat splashes to eyes and skin immediately. If accidentally ingested, seek medical attention. Reseal containers after use. Use in well ventilated areas and avoid inhalation.

Request the safety data sheet