KingCoat PE200®
Two component solvent free coal tar epoxy resin coating system.
SpecWorld has the Spec Pack, CSI specification and drawings for registered specifiers.
Overview
KingCoat PE200 is a two component, solvent free, amine cured coal tar epoxy. The product has excellent chemical resistance properties which makes it particularly suitable for aggressive environments such as sewage treatment plants and sewage manholes. KingCoat PE200 is suitable for use on concrete and steel surfaces.
Where to use
KingCoat PE200 provides chemical and abrasion resistance to prevent corrosion of concrete surfaces. Typical applications include:
- Seawater tanks, channels and intakes.
- Manhole linings.
- Sewage and effluent plants.
- Chemical processing areas.
- Building foundations waterproofing.
- Jetties, piers and docks.
*Not suitable for surfaces in contact with drinking water.
Why use it
- Excellent adhesion to concrete, steel and asphalt surfaces.
- Cost effective; does not require primer.
- Suitable for use as a waterproof coating.
- High chemical resistance.
- Does not support bacterial growth.
- High abrasion resistance.
- Can be applied to green concrete.
Technical properties
| Colour | Black |
|---|---|
| Mixed density | 1.55 ± 0.05 g/cm³ @ 25°C |
| Mixing ratio | 1:1 |
| Pot life | 50 – 80 min @ 25°C 25 – 35 min @ 35°C |
| Tack free time | 3 - 4 hr @ 25°C 2 - 3 hr @ 35°C |
| Over- coating time | 8 – 10 hr @ 25°C 6 – 8 hr @ 35°C |
| Full cure | 7 days @ 25°C 4 days @ 35°C |
| Water permeabilityDIN 1048 2 bars @ 100 days | Nil |
| Salt spray testBS 1881/124 : 1988 Over 1000 hr | Nil @ 200 microns thickness |
| Bond strengthBS 1881, Part 207 | > 2 MPa (concrete Failure) |
| Water absorptionASTM D570 | < 0.1% |
| VOC | ≤ 50 g/ltr (Comply with LEED) |
How to use
Method of use
Substrate Preparation
Concrete surfaces
The substrate should be sound, clean and free from
contamination. Surface laitance should be removed by grit blasting or water jetting. All exposed blow holes should be filled with epoxy paste using KingRep EP10.
Steel surfaces
All surfaces should be grit blasted to reach a bright
finish.
Mixing
To ensure proper mixing, a mechanically powered mixer or drill fitted with suitable paddle should be used. Stir the content of each component separately to disperse any settlement. Mix both hardener and base together for 3 minutes in a separate container and until uniform colour and consistency is achieved.
Application
KingCoat PE200 can be applied by brush and roller. The first coat should be applied to obtain a continuous uniform coating. The second coat should be applied within the over coating time to achieve the maximum adhesion between the two coats.
Cleaning
All tools should be cleaned immediately after application using DPC solvent. Hardened materials must be cleaned mechanically.
Limitations and notes
For hot climate application, the following guidelines must be adopted as a prudent working regime:
- The unmixed materials should be stored in a cool (preferably temperature controlled) environment, avoiding exposure to direct sunlight.
- The mixing and placing equipment should be kept cool; shade protection should be arranged if necessary. It is especially important to keep cool, the equipment surfaces which will come into direct contact with the material itself.
- Application in the middle of the day should be avoided and must not be carried out under direct sunlight.
- For hand application, it should be ensured that sufficient operatives are available to complete the application within the pot life of the material.
- If application is carried out in cold weather (below 15°C), the materials should be stored in a heated building and only removed immediately before use.
- Accelerated heating methods must not to be used under any circumstances.
Coverage, packaging and storage
Coverage
Approximately 0.33 kg/m² per coat to achieve 200 microns DFT.
| Chemical Resistance after full cureASTM D1308 (after 7 days immersion in the below chemicals) | |
|---|---|
| Inorganic Bases | |
| Sodium Hydroxide 50% | R |
| Ammonia Solution 10% | R |
| Potassium Hydroxide 50% | R |
| Aqueous Solutions | |
| Sodium Chloride sat | R |
| Tap water | R |
| Chlorinated water | R |
| Dead sea water | R |
| Oils & Fuels | |
| Benzyl alcohol | R |
| Brake fluid | R |
| Engine oil | R |
| Diesel | R |
| Kerosene | R |
| Detergents & Soaps | R |
| Inorganic Acids | |
| Sulphuric Acid 25% | R |
| Nitric Acid 10% | R |
| Lactic Acid 10% | SS |
| HCL 10% | SS |
| Phosphoric Acid 20% | R |
| Vinegar 5% | SS |
R: Resistant
RS: Resistant with slight discoloration
SS: Slight softining
Packaging
KingCoat PE200 is available in 14 kg packs (9 litre).
Storage
Shelf life is 1 year when stored under cover, out of direct sunlight and protected from extremes of temperature. Failure to comply with the recommended storage conditions may result in premature deterioration of the product or packaging. For specific storage advice consult KingKrete's Technical Services Department.
Health and safety
As with all chemical products, care should be taken during use and storage to avoid contact with eyes, mouth, skin and foodstuffs. Treat splashes to eyes and skin immediately. If accidentally ingested, seek medical attention. Reseal containers after use. Use in well ventilated areas and avoid inhalation.