KingCoat PE100®
Two component high solids coal tar epoxy resin coating system.
SpecWorld has the Spec Pack, CSI specification and drawings for registered specifiers.
- Bond strength ASTM D4541
- ≥ 1.5 MPa
- Mixed density
- 1.0 g/cm³
- Solid contents
- 91 ± 2%
Overview
KingCoat PE100 is a two component amine cured coal tar epoxy. The product has excellent chemical resistance properties which makes it particularly suitable for sewage treatment plants and for aggressive environments. KingCoat PE100 is suitable for use on concrete, steel and asphalt surfaces.
Where to use
KingCoat PE100 is designed for use in applications such as:
- Waterproofing applications on concrete substrates.
- Lining of manholes, pipes, jetties, piers, ducting and foundations waterproofing.
- Sewage treatment plants.
- Protection of concrete and steel structures submerged in sea water or exposed to tidal or splash zones.
Why use it
- Excellent adhesion to concrete, steel and asphalt surfaces.
- Cost effective; does not require primer.
- Suitable for use as a waterproof coating.
- High chemical resistance.
- Does not support bacterial growth.
- High abrasion resistance.
- Can be applied to green concrete.
Technical properties
Values @ 25º
| Mixed density | 1.0 g/cm³ |
|---|---|
| Solid contents | 91 ± 2% |
| Colour | Black |
| Abrasion & impact resistanceBS 3900 - E3 | Passed |
| Bond strengthASTM D4541 | ≥ 1.5 MPa |
| Pot life | 3 - 4 hr @ 25°C 1 - 2 hr @ 35°C |
| Re-coatable time | 24 hr @ 25°C Within 12 hr @ 35°C |
| Full cure | After 7 days @ 25°C |
| Water absorptionASTM D570 | < 0.1% |
| Service temperature | -10 to 55°C |
| VOCASTM D2369 | < 150 g/ltr |
How to use
Method of use
Substrate Preparation
Concrete surfaces
The Substrate should be sound, clean and free from
contamination. Surface Laitance should be removed by sand or grit blasting and/or water jetting. All exposed blow holes should be filled with epoxy paste using KingRep EP10.
Steel surfaces
All surfaces should be grit blasted to reach a bright finish meeting the requirement of Swedish Standard SA 2 1/2.
Mixing
To ensure proper mixing, a mechanically powered mixer or drill fitted with suitable paddle should be used. Stir the content of each component separately to disperse any settlement. Add the entire content of the base to the hardener and mix for 3 minutes and until a uniform colour and consistency are achieved.
Application
KingCoat PE100 can be applied by brush; roller and airless spray machine. The first coat should be applied to obtain a continuous uniform coating. The second coat should be applied within the over coating time to achieve the maximum adhesion between coats.
Cleaning
All tools should be cleaned immediately after application using KINGKRETE Solvent. Hardened materials must be cleaned mechanically.
Limitations and notes
- The area where KingCoat PE100 is applied must be protected from any contact with water for at least 30 hours after application. Otherwise discolouration may occur. Also, in closed areas where the relative humidity is very high, good ventilation is needed and precaution must be taken to insure the full cure of the material.
- KingCoat PE100 must not be applied over other coatings, but can be applied on top of itself within the over coating times (mentioned above).
- For temperatures around 5°C, the unmixed material needs to be heated before the application. Heating is done by storing packs in a heated area.
Coverage, packaging and storage
Coverage
Approximately 0.22 kg/m²/coat.
Two coats should be applied to achieve 400 microns dry film thickness.
Packaging
KingCoat PE100 is available in 18 kg packs.
Storage
Shelf life is 1 year when stored under cover, out of direct sunlight and protected from extremes of temperature. Failure to comply with the recommended storage conditions may result in premature deterioration of the product or packaging. For specific storage advice consult KingKrete's Technical Services Department.
| Chemical Resistance after full cureASTM D1308 (after 7 days immersion in the below chemicals) | |
|---|---|
| Organic acids | |
| Acetic Acid 10% | SS |
| Lactic Acid 10% | SS |
| Oleic Acid sat. | R |
| Citric Acid 25% | R |
| Vinegar 10% | R |
| Inorganic Bases | |
| Sodium Hydroxide 50% | R |
| Ammonia Solution 10% | R |
| Potassium Hydroxide 50% | R |
| Aqueous Solutions | |
| Sodium Chloride sat | R |
| Tap water | R |
| Chlorinated water | R |
| Dead sea water | R |
| Solvents | |
| White spirit | SS |
| Xylene | SS |
| Toluene | R |
| Oils & Fuels | |
| Benzyl alcohol | SS |
| Brake fluid | SS |
| Engine oil | R |
| Diesel | R |
| Kerosene | R |
| Detergents & Soaps | R |
| Inorganic Acids | |
| Sulphuric Acid 25% | SS |
| Phosphoric Acid 20% | R |
| Hydrochloric Acid 10% | R |
| Nitric Acid 10% | SS |
R: Resistant
RS: Resistant with slight discoloration
SS: Slight softining
Health and safety
As with all chemical products, care should be taken during use and storage to avoid contact with eyes, mouth, skin and foodstuffs. Treat splashes to eyes and skin immediately. If accidentally ingested, seek medical attention. Reseal containers after use. Use in well ventilated areas and avoid inhalation.