KingGrout PG300®
High strength pourable epoxy resin grout.
SpecWorld has the Spec Pack, CSI specification and drawings for registered specifiers.
Overview
KingGrout PG300 is a three component, high strength, and free flowing epoxy resin grout. KingGrout PG300 is suitable for grouting large gaps from 10 to 400 mm at high ambient temperatures of up to 55°C.
Where to use
KingGrout PG300 is ideally designed for use in the following applications:
- Machine base plates.
- Heavy crane rails.
- Bearing plinths.
- Anchoring of steel fixings.
- High speed turbines.
- Grouting areas where occasional chemical spillage may occur.
Why use it
- Resistant to dynamic loading.
- Non-shrink and low creep characteristics under continuous loading.
- Exceptional high compressive, flexural and tensile strengths.
- Extremely dense.
- Exceptional bond to concrete and steel surfaces.
- Good chemical resistance.
- High ultimate and early strengths.
Technical properties
| Mixed density | 2.00 ± 0.1 g/cm³ |
|---|---|
| Working life | 80 ± 10 min @ 25°C 40 ± 10 min @ 40°C |
| Compressive strengthASTM C579 @ 1 day @ 3 days @ 7 days | ≥ 50 MPa @ 25°C ≥ 75 MPa @ 40°C ≥ 70 MPa @ 25°C ≥ 85 MPa @ 40°C ≥ 85 MPa @ 25°C ≥ 95 MPa @ 40°C |
| Flexural strengthEN 13892-2 @ 7 days | ≥ 35 MPa @ 40°C |
| Tensile strengthBS 6319-7 @ 7 days | ≥ 15 MPa @ 40°C |
| Recommended working ambient temperature | 15 - 55°C |
| Crack formation temperature @ 400 mm | No cracks or bleeding |
| Peak exothermic temperatureASTM D2471 | 55 ± 2°C @40°C 66 ± 2°C @ 55°C |
| Peak exothermic time: ASTM D2471 | 35 ± 5 min @ 40°C 25 ± 5 min @ 55°C |
| Water absorption: ASTM C413 | ≤ 0.15% |
| Flow (using 200 ml cone) | 200 ± 10 mm |
| VOCASTM D2369 | < 10 g/ltr (complies with LEED) |
Care should be taken to ensure that the bottom and the product sides are thoroughly scraped and used. Mix the two components for 2 minutes. The filler should be gradually added while mixing. Mixing should continue for 3 minutes or until a uniform consistency obtained.
THICKNESSES AND SIZE LIMITATIONS
KingGrout PG300 is suitable for grouting large gaps from 10 to 400 mm. For greater thicknesses, multiple layers can be applied after initial curing of the previous layer.
PLACING AND FINISHING
Under Base plate
Enough material should be available to achieve a continuous fill and to complete the work. Pouring of the mixed grout should be started from one side only to avoid air entrapment. To obtain maximum flow distance, a side shutter feed with 100 mm side height should be erected and used to build the required head. At 100 mm of head, a flow distance of 2100 mm can be achieved at gap thicknesses of 100 mm @ 25°C ambient temperatures.
Formwork
As the mixed grout possesses high fluid characteristics, all formwork and shutters should be water tight. This can be achieved by sealing underneath the formwork and at the joints by using an appropriate mastic.
How to use
Substrate preparation
- The Substrate should be sound, clean and free from contamination. Surface laitance should be removed by scabbling or grit blasting.
- Steel surfaces should be grit blasted to remove all rust and scale.
- Concrete surfaces should be dry.
- Holes drilled for anchor bolts should be thoroughly cleaned from dust and lose debris using suitable brush or compressed air.
Mixing
To ensure proper mixing, a mechanically powered mixer or drill fitted with helix type paddle should be used. The entire content of the Hardener pack should be added to the Base pack.
Cleaning
All tools should be cleaned immediately after finishing using a suitable epoxy thinner. Hardened materials should be cleaned mechanically.
Limitations and notes
If temperatures are less than 20°C, the cure rate will be slow, but eventually will go to completion if the temperatures remain above 15°C.
Coverage, packaging and storage
Packaging
KingGrout PG300 is available in 30 kg packs (15 litre).
Storage
Shelf life is 1 year when stored under cover, out of direct sunlight and protected from extremes of temperature.
Failure to comply with the recommended storage conditions may result in premature deterioration of the product or packaging. For specific storage advice consult KingKrete's Technical Services Department.
Health and safety
As with all chemical products, care should be taken during use and storage to avoid contact with eyes, mouth, skin and foodstuffs. Treat splashes to eyes and skin immediately. If accidentally ingested, seek medical attention. Reseal containers after use. Use in well ventilated areas and avoid inhalation.