KingGrout PE10 is a two components, high strength, fast cure, polyester resin anchoring grout.
Where to use
KingGrout PE10 is ideally designed for use in the following applications:
- Permanent installation of reinforcement starter bars and dowel bars.
- Permanent installation of hand rails, safety fence, wall ties, railway tracks and ground anchors.
Why use it
- Exceptional rapid strength development.
- Resistant to dynamic loading.
- Damp tolerant. The product will cure under damp conditions and is resistant to immersion underwater.
- Exceptional high compressive, flexural and tensile strengths.
- Extremely dense.
- Exceptional bond to concrete and steel surfaces.
- Good chemical resistance.
- High ultimate and early strengths. Available into two grade, KingGrout PE10 H (Horizontal) and KingGrout PE10 V (Vertical).
Technical properties
| Compressive strength: BS6319, Part 2 : 1983 | ≥ 70 MPa @ 1 hr ≥ 100 MPa @ 24 hr ≥ 115 MPa @ 7 days |
|---|---|
| Flexural strength BS6319, Part 3 : 1990 | ≥ 25 MPa @ 7 days |
| Tensile strength BS6319, Part 7 : 1985 | ≥ 14 MPa @ 7 days |
| Working life | 90 min @ 10°C 35 min @ 20°C 14 min @ 30°C |
| Bond strength | When applied properly, failure in pull will be in the concrete or steel, and not at the bond interface. |
Mixing shall continue for 3 minutes or until a uniform consistency is obtained.
PLACING AND FINISHING
Vertical Application
KingGrout PE10 V should be used for vertical applications. The mixed material should be poured into the prepared holes. The bar/bolt should then be pressed and twisted into the grout.
Horizontal Application
KingGrout PE10 H should be used for horizontal applications. Grouting can be carried out by filling the materials into plastic Cartridges and then injected using a skeleton gun. Once the grout is injected, the bar/bolt should be pressed and twisted into the grout.
Care should be taken to ensure that the bottom and the side are thoroughly scraped and transferred. The filler shall be gradually added to the plastic container containing the resin while mixing.
| TABLE I | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| FY (N/mm²) | FC (N/mm²) | ΦB (mm) | ΦH (mm) | Calculated Pullout Force F(KN) in tension with 40% safety margin at a certain hole depth (HD) | Ultimate Pullout Force in tension | |||||||
| For Steel Bar | For Concrete | Bar Diameter | Hole Diameter | 100 | 120 | 160 | 200 | 250 | 300 | 350 | Hole Depth (mm) | F (KN) |
| 420 | 2.5 | 8 | 12 | 16 | 19 | 25 | 134 | 21 | ||||
| 420 | 2.5 | 10 | 14 | 18 | 22 | 29 | 37 | 180 | 33 | |||
| 420 | 2.5 | 12 | 16 | 21 | 25 | 33 | 42 | 52 | 227 | 47 | ||
| 420 | 2.5 | 14 | 18 | 24 | 28 | 38 | 47 | 59 | 275 | 65 | ||
| 420 | 2.5 | 16 | 20 | 26 | 31 | 42 | 52 | 65 | 78 | 323 | 84 | |
| 420 | 2.5 | 18 | 22 | 29 | 35 | 46 | 58 | 72 | 86 | 101 | 371 | 107 |
| 420 | 2.5 | 20 | 24 | 31 | 38 | 50 | 63 | 78 | 94 | 110 | 420 | 132 |
| 420 | 2.5 | 22 | 26 | 34 | 41 | 54 | 68 | 85 | 102 | 119 | 469 | 160 |
| 420 | 2.5 | 25 | 30 | 39 | 47 | 63 | 78 | 98 | 118 | 137 | 525 | 206 |
| 420 | 2.5 | 32 | 36 | 47 | 56 | 75 | 94 | 118 | 141 | 165 | 717 | 338 |
C)Table II shown below shows the Ultimate Pullout Force that each steel reinforcement bar grade 60 can take:
| TABLE II | |||
|---|---|---|---|
| Dar Diameter ΦB mm | Bar Area mm | FY N/ mm² | Ultimate Pullout Force (F) KN |
| 8 | 50.24 | 420 | 21 |
| 10 | 78.5 | 420 | 33 |
| 12 | 113.04 | 420 | 47 |
| 14 | 153.86 | 420 | 65 |
| 16 | 200.96 | 420 | 84 |
| 18 | 254.34 | 420 | 107 |
| 20 | 314 | 420 | 132 |
| 22 | 379.94 | 420 | 160 |
| 25 | 490.625 | 420 | 206 |
| 32 | 803.84 | 420 | 338 |
D)To calculate volume of KingGrout PE10 required in ML:
Volume (ML) = π . (ΦH² – ΦB² ) . HD
4000
| TABLE III | |||||||||
|---|---|---|---|---|---|---|---|---|---|
| Volume of KINGGROUT PE10 REQUIRED (ML) Hole Depth (mm) | |||||||||
| Bar Dia mm | Hole Dia mm | 100 | 140 | 160 | 200 | 250 | 300 | 350 | 400 |
| 8 | 12 | 6 | 9 | 10 | 13 | 16 | 19 | 22 | 25 |
| 10 | 14 | 8 | 11 | 12 | 15 | 19 | 23 | 26 | 30 |
| 12 | 16 | 9 | 12 | 14 | 18 | 22 | 26 | 31 | 35 |
| 16 | 20 | 11 | 16 | 18 | 23 | 28 | 34 | 40 | 45 |
| 20 | 25 | 18 | 25 | 28 | 35 | 44 | 53 | 62 | 71 |
| 25 | 32 | 31 | 44 | 50 | 63 | 78 | 94 | 110 | 125 |
| 32 | 40 | 45 | 63 | 72 | 90 | 113 | 136 | 158 | 181 |
| 40 | 50 | 71 | 99 | 113 | 141 | 177 | 212 | 247 | 283 |
Table III shows an estimate of materials required for each bar for a given hole depth and diameter.
DESIGN CONSIDERATION
A)Minimum Hole Depth HD
As per BS8110, minimum Hole Depth HD (or length of embedment) is shown below, allowing for 40% factor of safety
HD= 0.6 FY . π ΦB²
FC π ΦH 4
HD= 0.6 . FY . ΦB²
4 FC ΦH
Noting that:
FY: Yield strength of the steel (N/mm²)
FC: Concrete bond stress (N/ mm²)
ΦB: Bar Diameter (mm)
ΦH: Hole Diameter (mm)
HD: Minimum Hole Depth (length of Embedment) (mm)
π: 3.14
B)Calculation of the Pullout Force (F) in tension using the minimum hole depth (HD) shown in A is as follows:
HD= 0.6 . FY . ΦB²
4 FC ΦH
FC π ΦH HD = 0.6 FY . π ΦB²
4
The Pullout Force (F) is equal to FY * Steel Bar Area. The Steel Bar Area is equal to:
π ΦB²
4
then:
FC π ΦH HD = 0.6 F
F (N) = π . FC . ΦH . HD
0.6
F (KN) = (5.23 . FC . ΦH . HD¹) ÷ 1000
Table I is a summary of the forces (F) that each steel reinforcement bar can take for a certain hole depth (HD).
Calculations are based on steel grade 60 and 25 N/ mm² concrete compressive strength with FC at 2.5 N/ mm².
ESTIMATING
The required quantity of grout needed is dependent on hole diameter, bar diameter and hole depth. This can be estimated by using the following formula:
Volume of grout (ml) = 3.14 * (Dh² – Db²) * H
4
Where:
Dh is hole diameter in mm.
Db is bar diameter in mm.
H is hole depth in mm
How to use
Substrate preparation
Substrate should be sound, clean and free from grease or any contamination. Bars should be free from any loose rust deposits. Holes are best made using rotary percussive drill to provide rough sides followed by air or water flushing. If hole is cast, it should be of inverse dovetail configuration or mechanically roughened to provide a key. Deformed or ribbed bars will give a higher performance than smooth or other bar types.
Mixing
To ensure proper mixing, a mechanically powered mixer or drill fitted with suitable paddle should be used. The entire content of the resin should be transferred to a plastic container.
Cleaning
All tools should be cleaned immediately after finishing by KINGKRETE Solvent. Hardened materials can be cleaned mechanically.
Coverage, packaging and storage
Packaging
KingGrout PE10 is available in 1.2 litre packs.
Storage
Shelf life is 1 year when stored under cover, out of direct sunlight and protected from extremes of temperature.
Failure to comply with the recommended storage conditions may result in premature deterioration of the product or packaging. For specific storage advice consult KingKrete's Technical Services Department.
Health and safety
As with all chemical products, care should be taken during use and storage to avoid contact with eyes, mouth, skin and foodstuffs. Treat splashes to eyes and skin immediately. If accidentally ingested, seek medical attention. Reseal containers after use. Use in well ventilated areas and avoid inhalation.