🌍 🌐 English
Grouts & Anchors

KingGrout AE10®

Epoxy acrylate resin cartridge system for anchoring.

SpecWorld has the Spec Pack, CSI specification and drawings for registered specifiers.

Overview

KingGrout AE10 is a high strength, fast cure, styrene free, epoxy acrylate resin anchoring grout supplied in a pre- packed cartridge system. It is suitable for use with different types of substrates such as concrete, hard natural stone, solid rock and solid masonry.

Where to use

KingGrout AE10 is ideally designed for use in the following applications:

  • Permanent installation of reinforcement starter bars and dowel bars.
  • Permanent installation of hand rails, safety fence, wall ties, rail way tracks and ground anchors.
  • Bonding concrete reinforcing bars and securing profiled sections and bars.

Why use it

  • Use standard sealant application gun.
  • Exceptional rapid strength development.
  • Styrene free.
  • Resistant to dynamic loading.
  • Exceptional bond to concrete and steel surfaces.
  • High ultimate and early strengths.
  • Applicable at low temperature from -5°C.
  • Low waste, reusable and easily recycled cartridge.

How to use

Substrate preparation

Substrate should be sound, clean and free from grease or any contaminants. Bars should be free from any loose rust deposits. Holes can be drilled using a hammer drill to produce a rough surface or by coring to produce a smooth surface. Deformed or ribbed bars will give a higher performance than smooth or other bar types. After drilling, holes should be brushed and blown out twice, to remove all drilling debris.

Resin Cartridge TemperatureWorking timeBase material temperatureLoading time
Min 5°C12 min-5 to 0°C24 hr
Min 5°C12 min0 to 5°C180 min
5 to 10°C8 min5 to 10°C100 min
10 to 20°C4 min10 to 20°C70 min
20 to 25°C3 min20 to 25°C40 min
25 to 30°C2 min25 to 30°C40 min
+30°C1 min+30°C40 min

Notes: Working time is set at the highest base material temperature in the range.
Loading time is set at the lowest base material temperature in the range.
May be used at low temperatures (minimum application of -5°C) if the cartridge/resin temperature is kept above 5°C.

Application

Unscrew the protective cap, cut the film to remove the metal clip and attach the static mixing nozzle. Insert the cartridge into the cartridge gun and dispense sufficient material until an even colour is achieved. Usually 10 ml of extruded material should be adequate.

Insert the nozzle into the base of the hole, apply pressure to the gun and slowly withdraw the nozzle as the hole fills. Normally it is enough to fill the hole approximately half to two thirds full. Insert the stud/steel bar into the hole with a twisting action, ensuring that is fully embedded. Allow the resin to cure fully before loading.

When filling holes overhead or in porous block work, the use of plastic sleeves is recommended. Partly used cartridge are reusable, Remove the static mixer and surplus base and catalyst components from the cartridge nozzle, insert the plug and screw on the protective cap.

TABLE I
FY
(N/mm²)
FC
(N/mm²)
ΦB (mm)ΦH
(mm)
Calculated Pullout Force F(KN) in tension with 40% safety margin at a certain hole depth (HD)Ultimate Pullout
Force in tension
For steel barFor concreteBar diameterHole diameter100120160200250300350Hole Depth
(mm)
F (KN)
4202.581216192513421
4202.510141822293718033
4202.51216212533425222747
4202.51418242838475927565
4202.5162026314252657832384
4202.51822293546587286101371107
4202.52024313850637894110420132
4202.522263441546885102119469160
4202.525303947637898118137525206
4202.5323647567594118141165717338
TABLE II
Dar Diameter ΦB
mm
Bar Area
mm
FY
N/mm²
Ultimate Pullout Force
(F) KN
850.2442021
1078.542033
12113.0442047
14153.8642065
16200.9642084
18254.34420107
20314420132
22379.94420160
25490.625420206
32803.84420338
TABLE III
Volume of KINGGROUT REQUIRED (ML) Hole Depth (mm)
Bar Dia
mm
Hole Dia
mm
100140160200250300350400
81269101316192225
1014811121519232630
1216912141822263135
16201116182328344045
20251825283544536271
2532314450637894110125
324045637290113136158181
40507199113141177212247283

Table III shows an estimate of materials required for each bar for a given hole depth and diameter.

DESIGN CONSIDERATION

A)Minimum Hole Depth HD

As per BS8110, minimum Hole Depth HD (or length of embedment) is shown below, allowing for 40% factor of safety.

HD= 0.6 FY . π ΦB² FC

π ΦH 4

HD= 0.6. FY. ΦB²

4 FC ΦH

Noting that:

FY: Yield strength of the steel (N/mm²)

FC: Concrete bond stress (N/mm²)

ΦB: Bar Diameter (mm)

ΦH: Hole Diameter (mm)

HD: Minimum Hole Depth (length of Embedment) (mm)

π: 3.14

B)Calculation of the Pullout Force (F) in tension using the minimum hole depth (HD) shown in A is as follows:

HD= 0.6 . FY. ΦB²

4 FC ΦH

FC π ΦH HD = 0.6 FY . π ΦB²

4

The Pullout Force (F) is equal to FY * Steel Bar Area. The Steel Bar Area is equal to:

π ΦB²

4

then:

FC π ΦH HD = 0.6 F

F (N) = π . FC . ΦH . HD

0.6

F (KN) = (5.23 . FC . ΦH . HD¹) ÷ 1000

Table I is a summary of the forces (F) that each steel reinforcement bar can take for a certain hole depth (HD).

Calculations are based on steel grade 60 and 25 N/mm² concrete compressive strength with FC at 2.5 N/mm².

C)Table II shown below shows the Ultimate Pullout Force that each steel reinforcement bar grade 60 can take

D)To calculate volume of KingGrout AE10 required in mL: Volume (mL) = π . (ΦH² – ΦB² ) . HD

4000

Cleaning

All tools should be cleaned immediately after finishing. Hardened materials can be cleaned mechanically.

ESTIMATING

The required quantity of grout needed is dependent on hole diameter, bar diameter and hole depth. This can be estimated by using the following formula:

Volume (ML) = π . (ΦH² – ΦB²) . HD

4000

Where:

ΦH is hole diameter in mm.

ΦB is bar diameter in mm. H is hole depth in mm.

Coverage, packaging and storage

Packaging

KingGrout AE10 is available in 300 ml.

Storage

Shelf life is 1 year when stored under cover, out of direct sunlight and protected from extremes of temperature.

Failure to comply with the recommended storage conditions may result in premature deterioration of the product or packaging. For specific storage advice consult KingKrete's Technical Services Department.

Health and safety

As with all chemical products, care should be taken during use and storage to avoid contact with eyes, mouth, skin and foodstuffs. Treat splashes to eyes and skin immediately. If accidentally ingested, seek medical attention. Reseal containers after use. Use in well ventilated areas and avoid inhalation.

Request the safety data sheet