🌍 🌐 English
Joint Sealants

KingSeal PS300®

Elastomeric high-performance cold-applied fuel resistant pavement joint sealant.

SpecWorld has the Spec Pack, CSI specification and drawings for registered specifiers.

Tensile strength ASTM D412, Die C
≥ 0.50 MPa @ 7 days
Elongation at break ASTM D412, Die C
≥ 290% @ 7 days
Shore A hardness ASTM D2240
≥ 25 @ 7 days
Pot life
80 - 90 min @ 25°C

Overview

KingSeal PS300 is a two-component, chemical curing, cold applied, fuel and oil resistant pitch-free polysulphide sealant designed for use in all types of concrete pavement joints and specifically for sealing joints in airport pavement construction. KingSeal PS300 has excellent adhesion properties to asphalt substrates.

Where to use

KingSeal PS300 is designed for:

  • Sealing all types of joints in airport runways and aprons.
  • Sealing all types of joints in car parks and traffic decks.
  • Sealing of all types of joints in warehouses, oil terminals, docks, and harbours.
  • Sealing all types of joints in sewage treatment plants.
  • Suitable for horizontal joints only.

Why use it

  • Pitch-free
  • Fuel and oil resistance.
  • Cold applied chemical curing sealant.
  • Suitable for all climate conditions, weathering, and UV resistance.
  • Suitable for manual and machine processing
  • Excellent movement accommodation.
  • Pourable and self-leveling.
  • Good chemical resistance to a wide range of mild
  • alkalis, diluted acids, and solvents.

Technical properties

ColourBlack and grey
Mixed density1.45 ± 0.05 g/cm³
Solid content100%
Application temperature5 to 40°C
Pot life80 - 90 min @ 25°C
Movement accommodation25%
Curing timeChemical cure
Tack free time4 - 5 hr
Service temperature-40 to 90°C
Shore A hardnessASTM D2240≥ 25 @ 7 days
Elongation at breakASTM D412, Die C≥ 290% @ 7 days
Tensile strengthASTM D412, Die C≥ 0.50 MPa @ 7 days
VOC< 50 g/ltr

Chamfer the joint edges with a face width of 3 to 10 mm. After cleaning, a backing rod of an appropriate size should be placed in the joint to the required depth to ensure proper layer thickness and prevent three-point adhesion. Care should be taken not to puncture the backing rod during installation as punctures might create bubbling.

Standards and approvals

US Federal Specification SS-S-200E:1984.

» British standard 5212:1990, Type N, F and FB.

» ASTM C920, Type M, Grade P, Class 25, Use NT, T1, M and I.

How to use

Substrate preparation

Concrete surfaces must be sound, dry, dimensionally stable, and fully cured (not subject to shrinkage). All surfaces should be clean of dirt, laitance, bitumen, foreign matter, and curing compounds. Substrate should be free from oil, grease, dust or, any contamination

Priming

KingSeal Primer Universal is a low viscosity single component primer suitable for use with porous and non-porous surfaces. It is recommended to be used for substrates such as concrete and asphalt as well as others.

Using a small brush apply one thin coat at the joint sides and avoid over priming. Apply the mixed KingSeal PS300 sealant while the primer is still tacky to achieve optimum adhesion strength.

Mixing

To ensure proper mixing, a mechanically powered mixer should be used. KingSeal PS300 is supplied in two components, Part A and Part B, with a mixing ratio of 5:1. The full quantity of the two components must be mixed thoroughly for 3 - 5 minutes.

Application

KingSeal PS300 should be applied using a suitable pump system with a 5:1 mixing ratio by volume. Refer to the pump manufacturer recommendations for application and inject the sealant with a continuous, smooth action starting at the bottom of the joint to the top.

Alternatively, the mixed sealant can be applied into the primed joints using an air-powered sealant gun, the sealant should be loaded into the gun after removing the cap and pulling back the plunger rod. Inject the sealant with a continuous, smooth action starting at the bottom of the joint to the top.

KingSeal PS300 is self-leveling and does not require finishing. The finished level of the sealant is recommended to be recessed below the trafficked surface as insufficient recess can expose the sealant to vehicle tires which might cause damage over time.

JOINT SIZE SUITABILITY

Joint width*

  • 10 mm (minimum).
  • 50 mm (maximum in trafficked areas).
  • 10 mm minimum.
  • 25 mm maximum.

Width: Depth ratio**

  • 2:1

* For wider joints please consult KINGKRETE Technical Department.

** Within above min/max restrictions.

Performance Characteristics in accordance with SS- S-200E
Self-levelingOn plane level< 3.2 mm (pass)
Self-levelingWith 1.5% inline< 1.6 mm (pass)
Change in mass by fuel immersion< 2% (pass)
Accelerated agingPass
Change in volume on exposure to elevated temperatures< 5% (pass)
ResilienceRecovery< 75% (pass)
ResilienceInitial
penetration
0.5 - 2.0 mm (pass)
Artificial weatheringNo surface softening Volume change < 5% (pass)
Bond to concrete: (water immersed & non- immersed)No cracking, separation
or crazing (pass)
Resistance to flamePass
FlowNo evidence of cracking, sag or dimensional change (pass)

REMARKS

  • While mixing and injecting the material, ensure not to incorporate too much air.
  • The curing speed depends on the temperature, as working in high ambient temperatures will cause the material to cure faster, while at low ambient temperature the material will take longer to cure.
  • Application should not be undertaken if the temperature is below 5°C.
Cleaning

All equipment should be cleaned immediately after finishing using an appropriate solvent. Hardened sealants should be removed mechanically.

Coverage, packaging and storage

Packaging

KingSeal PS300 is available in 4 ltr (5.8 kg), and 12 ltr (17.4 kg) kits.

KingSeal Primer Universal is available in 1, 4 and 20 ltr packs.

Storage

Shelf life is 1 year when stored under cover, out of direct sunlight and protected from extremes of temperature.

Failure to comply with the recommended storage conditions may result in premature deterioration of the product or packaging. For specific storage advice consult KingKrete's Technical Services Department.

CHEMICAL RESISTANCE
Occassional spillage after full cure (7 days @ 25°C), ASTM D1308 (Spot - test @ 1 hr)
Organic acids
Citric Acid 25%RS
Aqueous solutions
Sodium Chloride satR
Tap waterR
Chlorinated waterRS
Dead sea waterR
Solvents
White spiritR
XyleneR
TolueneR
AcetoneR
Oils & fuels
Brake fluidR
Engine oilR
DieselR
KeroseneR
Jet fuelR
PetroR
Hydraulic oilR
Mineral oilsR
Inorganic acids
Sulphuric Acid 25%RS
Hydrochloric Acid 10%RS
Nitric Acid 10%RS

R: Resistant
RS: Resistant with slight discoloration
SS: Slight softining

Health and safety

As with all chemical products, care should be taken during use and storage to avoid contact with eyes, mouth, skin and foodstuffs. Treat splashes to eyes and skin immediately. If accidentally ingested, seek medical attention. Reseal containers after use. Use in well ventilated areas and avoid inhalation.

SEALANT QUANTITY ESTIMATOR

Joint size (mm) width x depthMeters per litre
10 x 1010.00
13 x 135.91
15 x 154.44
20 x 105.00
20 x 202.50
25 x 123.33
25 x 251.60
30 x 152.22
40 x 201.25
50 x 250.80

Note: actual consumption depends on the nature of substrate, method of application, and wastage.

Request the safety data sheet