KingSeal EPU200®
Two component, Epoxy-urethane self-levelling sealant.
SpecWorld has the Spec Pack, CSI specification and drawings for registered specifiers.
- Elongation at break ASTM D2240
- > 130% @ 28 days
- Shore A hardness
- 80 ± 5
- Pot life
- 45 min @ 25°C
- Specific gravity
- 1.30 ± 0.05
Overview
KingSeal EPU200 is a two-component 100% solids sealant, designed to withstand industrial loads and traffic with 10% movement accommodation factor.
KingSeal EPU200 is a chemical curing sealant with self- levelling properties giving it ideal characteristics for ease of applications in large joints.
Where to use
- Joints exposed to heavy loads and traffic.
- Joints in factories and warehouses.
- Control joints with low movement.
- Saw cut joints.
Why use it
- Withstands heavy industrial traffic.
- Excellent chemical resistance.
- Easily poured and self-levelling properties.
- Available in a range of colours.
- Suitable for wide joints.
Technical properties
| Colour | Various |
|---|---|
| Specific gravity | 1.30 ± 0.05 |
| Movement accommodation factor | 10% |
| Shore A hardness | 80 ± 5 |
| Application temperature | 10 - 35°C |
| Tack-free time | 12 hr |
| Pot life | 45 min @ 25°C |
| Full cure | 4 days @ 25°C |
| Elongation at breakASTM D2240 | > 130% @ 28 days |
| Tensile strength at breakASTM D2240 | 1.9 MPa |
How to use
Substrate preparation
Concrete must be even, clean, dry, free from dust, oil, grease and any other contaminates that could affect the bond. It is recommended to clean the concrete with a metal brush and to dust it off using an air blower. To achieve a clean joint finish, apply masking tape on the sides of the joint.
Priming
KingSeal EPU200 doesn’t require any primer procedure. If the joint will be submerged in water, KingFloor Primer should be used prior to the application of the sealant.
Joint Backing
Where applicable, appropriate joint filler e.g. closed cell polyethylene foam should be used to provide the correct joint depth.
Mixing
To insure proper mixing, mechanically powered mixer or drill fitted with suitable paddle should be used. The components of KingSeal EPU200 should be thoroughly missed at low speeds of 300 rpm for 3 minutes while scraping the sides and bottom of the container making sure that all the components are mixed well.
Application
Mixed KingSeal EPU200 can be poured directly into the joint or can be placed using a sealant gun. The sealant should be extruded firmly into the joint while applying even pressure on the trigger when using a sealant gun. Avoid entrapping of air bubbles while applying, leave the sealant to settle in the joint and top up the level when needed.
Cleaning
All equipment should be cleaned immediately after the application using KINGKRETE solvent. Hardened sealants can be removed mechanically.
Limitations and notes
- KingSeal EPU200 should be applied after at least 28 days from the concrete pouring and preferably after 90 days.
- KingSeal EPU200 should only be used for horizontal joints.
- Do not apply KingSeal EPU200 in external applications.
Coverage, packaging and storage
Packaging
KingSeal EPU200 is available in a 4 litre pack.
CONSUMPTION IN JOINTS
| Joint size mm | Meters per Package |
|---|---|
| 6 x 6 | 110 |
| 12 x 12 | 26 |
| 25 x 12 | 12 |
| 30 x 15 | 8 |
| 50 x 25 | 2 |
Storage
Shelf life is 1 year when stored under cover, out of direct sunlight and protected from extremes of temperature.
Failure to comply with the recommended storage conditions may result in premature deterioration of the product or packaging. For specific storage advice consult KingKrete's Technical Services Department.
Health and safety
As with all chemical products, care should be taken during use and storage to avoid contact with eyes, mouth, skin and foodstuffs. Treat splashes to eyes and skin immediately. If accidentally ingested, seek medical attention. Reseal containers after use. Use in well ventilated areas and avoid inhalation.