🌍 🌐 English
Flooring

KingFloor EPH System

Medium to heavy duty high build epoxy floor coating for vehicle decking system

SpecWorld has the Spec Pack, CSI specification and drawings for registered specifiers.

Build-up

Applied in this order, from the substrate up. Layers drawn with a dashed outline are optional.

KingFloor EPH System, layer by layer
KingFloor EPH build-up Substrate1234
Not to scale. Thicknesses are shown for clarity.
No.ProductFunctionRate or thickness
SubstrateConcrete car park decks and ramps; sound, clean, RH < 75% (unless suspended deck free to dry from below)
1 KingFloor EP25 Medium-pile roller. Pre-fill defects with KingRep range / KingRep EP10 (not a layer). Light scarification if overcoated after 30 h. Primer 0.2 kg/m² (70 - 80 microns DFT)
2 KingFloor EP100 1 coat on traffic aisles/parking bays; 2 coats on ramps and turning circles. Base coat(s) 0.30 - 0.40 kg/m² per coat; 0.4 - 0.5 kg/m² when broadcast
3 KingFloor AS100 Optional Into the last wet base coat for anti-slip systems; excess removed before top coat. Broadcast aggregate (full blind) 2 - 3 kg/m²
4 KingFloor EP100 Applied over the blinded or smooth EP100 base coat. Top coat 0.30 - 0.40 kg/m²
Turn the build-up in 3D
Drag to turn. Click to separate the layers.

Build-up options

  • Ramps/turning circles, anti-slip: EP25 + EP100 + EP100 with full aggregate blind + EP100 top coat
  • Ramps/turning circles, smooth: EP25 + three coats EP100
  • Traffic aisles/parking bays, anti-slip: EP25 + EP100 with full aggregate blind + EP100 top coat
  • Traffic aisles/parking bays, smooth: EP25 + two coats EP100

About this system

KingFloor EPH is a hard wearing, epoxy base coating system primarily designed for use in car parks. It has excellent resistance to petrol, battery acid, diesel, brake fluid, de-icing salts, etc. KingFloor EPH System is formulated for easy application by roller or brush.

Where to use

  • Car park decks
  • Car park ramps and turning circles
  • Traffic aisles and parking bays
  • Road marking