🌍 🌐 English
Grouts & Anchors Systems

KingGrout HS100®

High strength cementitious precision grout.

C109/109M-11
MPa @ 28 days
C348
@ 28 days
Expansion characteristics
Up to 2%
Initial setting time @ 25oC
5 hr ASTM C191
ASTM C191
Coverage
13 – 14 litres/ 25 …
Packaging
Bag

Overview

KingGrout HS100 is a pre-mixed, pre-packed, high strength cementitious grout. It contains cement, selected additives, well graded, and non-reactive aggregate designed to give excellent flow properties, shrinkage compensation, and high compressive strength.

Applications

  • KingGrout HS100 is ideally designed for grouting areas where high temperature resistance and high early strength grout is required

Advantages

  • Non-shrink grout
  • Extremely dense and low permeability
  • High early strength development allowing for rapid installation
  • Good flow, can be poured or pumped into variable gab widths down to 10 mm
  • Easy to apply, single component which requires only addition of water
  • Chloride free
  • STANDARDS KingGrout HS100 complies with ASTM C1107, Grade A

Technical Properties

PropertyValueStandard
Compressive strengthASTM ≥ 40 MPa @ 1 day ≥ 75
C109/109M-11MPa @ 28 days
Tensile strength2 MPa @ 3 days 4 MPa @ 28 daysASTM C190
Flexural strengthASTM: 6.5 MPa @ 3 days 12 MPa
C348@ 28 days
ColourGrey
Expansion characteristicsUp to 2%
Bleeding: NilASTM C940
Initial setting time @ 25oC5 hrASTM C191
Final setting time @ 25oC6 hrASTM C191
Fresh wet density≈ 2.0 gm/ cm³
NotesTypical properties @ 3.75 litres/ 25 kg @ 25°C. *Compressive strength @ 1 day is under restrain. THICKNESSES AND SIZE LIMITATIONS KingGrout HS100 can be applied in a single layer at thicknesses between 10 – 100 mm. For greater thicknesses, an 8 – 12 mm washed aggregate should be added at a ratio of 15 kg of washed aggregates to 25 kg of KingGrout HS100. PLACING AND FINISHING
Under Base plateEnough material should be available to achieve continuous fill and to complete the work. Pouring of the mixed grout should be started from one side only to avoid air entrapment. To obtain maximum flow distance, a side shutter feed between 100 - 250 mm high should be erected and used to build the required head.
FormworkAs the mixed grout possesses good fluidity characteristics, all formworks and shutters should be water tight. This can be obtained by sealing underneath the formwork and at the joints by using appropriate mastic. The unrestrained areas should be kept at a minimum due to the expansion nature of KingGrout HS100.

Standards & Approvals

ASTM
ASTM C190
ASTM
ASTM C191
ASTM
ASTM C940
ISO
ISO 9001 · 14001 · 45001Quality & EHS

Usage & Packaging

Packaging

KingGrout HS100 is available in 25kg bags.

Coverage

Approximately 13 – 14 litres/ 25 kg bag depending on consistency.

Storage

Shelf life is 1 year when stored under cover, out of direct sunlight and protected from extremes of temperature

Pack formats

Bag