🌍 🌐 English
Concrete Repair & Strengthening

KingFiber CP System

Heavy duty carbon fibre reinforced polymer plate structural strengthening system

SpecWorld has the Spec Pack, CSI specification and drawings for registered specifiers.

Build-up

Applied in this order, from the substrate up. Layers drawn with a dashed outline are optional.

KingFiber CP System, layer by layer
KingFiber CP build-up Beam (section)soffit (underside), layers enlarged123
Not to scale. Thicknesses are shown for clarity.
No.ProductFunctionRate or thickness
SubstrateReinforced concrete, masonry, stonework, aluminium or timber members (beam/slab soffits); blast-cleaned, even within 10 mm per 2 m
1 KingRep EP20 Optional Only where surface defects exist. Epoxy putty / levelling of pinholes, honeycombs and irregularities
2 KingRep EP20 Thin layer on the substrate plus adhesive spread on the cleaned, ground side of the plate. Structural epoxy plate adhesive 0.15 kg/m (50 mm plate) to 0.44 kg/m (150 mm plate) at 2 mm thickness
3 KingFiber CP System Rolled in until adhesive squeezes out at the sides. Cure 7 days before renders or coatings. At crossings, grind the bottom plate CFRP plate (pultruded carbon laminate) 1.2 or 1.4 mm thick, 20-150 mm wide

Build-up options

  • CP100 series plates (E 165 GPa, 20-150 mm wide, 1.2/1.4 mm) or CP200 series (E 210 GPa, 50-150 mm wide, 1.4 mm): same build-up, only the plate grade changes
  • Adhesive consumption at 2 mm thickness varies with plate width: 0.15/0.17/0.23/0.26/0.29/0.35/0.44 kg/m for 50/60/80/90/100/120/150 mm

About this system

Heavy duty structural strengthening system based on carbon Fibers, the KingFiber CP System100 series is a number of products based on CFRP plates for use with reinforced concrete, masonry, stonework, aluminum and timber. The system is composed of CFRP plates and an epoxy adhesive to bond reinforcement (KingRep EP20).

Where to use

  • Increase of live and dead loads
  • Increase in traffic (dynamic loads)
  • Installation of industrial equipment and machinery
  • Insufficient structural members dimension
  • Lack of reinforcement steel
  • Seismic design requirements
  • Design loading standards change
  • Change in design approach
  • Statutory regulations change
  • Crack control
  • Deflection and deformation decrease
  • Steel reinforcement stress reduction
  • Structure renovation due to aging
  • Corrosion of reinforcement
  • Impact damage
  • Natural disaster damage
  • Openings in structural members
  • Removal of bearing members