KingInsulate C250®
Flexible cementitious adhesive base coat and protective top coat plaster for external wall insulating systems with improved bond strength, impact and water resistance.
SpecWorld has the Spec Pack, CSI specification and drawings for registered specifiers.
- Compressive strength EN 1015-11
- ≥ 8.0 MPa @ 28 days
- Flexural strength EN 1015-11
- ≥ 2.5 MPa @ 28 days
- Pot life
- 6 - 8 hr
Overview
KingInsulate C250 is a cementitious adhesive specially designed to be used for permanent fixing of thermal insulation boards to a wide range of substrates including concrete, and masonry.
KingInsulate C250 is also designed for use as a protective mortar providing a durable layer for insulation boards that is suitable to receive several types of decorative finishes.
Where to use
- For permanent fixing of expanded and extruded polystyrene boards to walls and roofs.
- For permanent fixing of mineral wool boards to walls and roofs.
- Provides a strong and smooth layer over thermal insulation boards.
- To be used with reinforcing mesh to form a solid layer to protect insulation boards.
- Suitable to receive a wide range of decorative finishes.
Why use it
- Easy to apply.
- Improved water resistance.
- Improved impact resistance.
- Non sag.
- Improved compressive strength.
- Improved bond strength.
- Requires no primer.
Technical properties
Values @25°C. W/P = 0.25
| Colour | Grey |
|---|---|
| Fresh wet density (mixed) | 1.7 ± 0.1 g/cm³ |
| Open time | 10 min @ 3 mm thickness |
| Pot life | 6 - 8 hr |
| Compressive strengthEN 1015-11 | ≥ 8.0 MPa @ 28 days |
| Flexural strengthEN 1015-11 | ≥ 2.5 MPa @ 28 days |
| Adhesion strength with concrete substrateEN 1015-12 | ≥ 1.5 MPa |
| Adhesion strength with EPS boards: EN 13494 | ≥ 150 KPa @ 28 days |
| Coefficient of water absorption by capillary-CEN 1015-18 | ≤ 0.1 kg/m².min⁰·⁵ |
| Thermal conductivity coefficientEN 1745, A12 | 0.9 W/m.K |
How to use
Substrate preparation
- All surfaces must be clean and free from oil, grease or loose materials.
- Substrate should be dimensionally stable. Allow time for shrinkage and structural strain movements.
- The insulation board has to be firmly fixed using KingInsulate C250adhesives and fasteners.
- Large gaps between insulation boards must be filled with strips of insulation board to leave minimal gaps.
- All edges of the building need to be protected by PVC, aluminum or stainless steel angle bars.
Priming
KingInsulate C250 can be applied directly on concrete, cement plaster and masonry. In case of very porous substrates, water should be sprayed onto surface prior to the application.
Mixing
To ensure proper mixing, a mechanically powered mixer or drill fitted with suitable paddle should be used.
Add 6.25 - 6.75 litres (for each 25 kg bags) of clean water to a clean container. The powder is then added slowly to the water while mixing continuously with low speed mixer/ drill (400 - 600 rpm). Mixing time should be continued for 3 minutes until a uniform consistency is obtained.
Application
As adhesive
Apply the mortar in a strip around the insulation board with a few spots in the middle. In case of a smooth base material, a toothed trowel can be used to spread the mortar on the back of the insulation board.
As protective layer
Apply the mortar over the fixed thermal insulation panel. Embed the precut reinforcing mesh onto the fresh applied mortar until it gets into the middle of the KingInsulate C250 layer. Smooth the surface with a long flat trowel. More than one KingInsulate C250 layer can be applied.
Note: Mesh strips have to be over lapped by approximately 10 cm.
Cleaning
All tools should be cleaned immediately after use with fresh clean water. Hardened materials can be cleaned mechanically.
Coverage, packaging and storage
Yield
As adhesive: Approximately 6 m²/25 kg bags at 3 mm thickness.
As protective layer: Approximately 3.75 m²/25 kg bag at 5 mm thickness.
Packaging
KingInsulate C250 is available in 25 kg bags.
Storage
Shelf life is 1 year when stored under cover, out of direct sunlight and protected from extremes of temperature. Failure to comply with the recommended storage conditions may result in premature deterioration of the product or packaging. For specific storage advice consult KingKrete's Technical Services Department.
Health and safety
As with all chemical products, care should be taken during use and storage to avoid contact with eyes, mouth, skin and foodstuffs. Treat splashes to eyes and skin immediately. If accidentally ingested, seek medical attention. Reseal containers after use. Use in well ventilated areas and avoid inhalation.