KingBond EP100PC®
Solvent free, two part epoxy adhesive for segmental concrete bridges.
SpecWorld has the Spec Pack, CSI specification and drawings for registered specifiers.
Overview
KingBond EP100PC is high viscosity, solvent free epoxy adhesive.
Quickmasst SBA is a two components product. Components are black and white in colour, when mixed turn into a uniform grey colour paste that bonds segmental concrete.
Where to use
KingBond EP100PC is used for bonding segmental concrete bridges. Its high bonding characteristics will improve construction speed and provide structurally sound and water tight joints.
Why use it
- Extremely high bond strength.
- Relativelly fast curing.
- Exhibit excellent squeezability.
- Damp tolerant.
- Available in four grades for different range of temperature application.
Technical properties
| Colour: FIP 5.11 Base Hardener Mixed | White Black Grey similar to adjoining concrete | |||||
|---|---|---|---|---|---|---|
| Mixed density | 1.70 ± 0.1 g/cm³ | |||||
| KingKrete | SBA 1 | SBA 2 | SBA 3 | SBA 4 | FIP Requirements | |
| Application temperature | 5 - 20°C | 15 - 30°C | 25 - 40°C | 35 - 60°C | ||
| Pot lifeFIP 5.1 | > 20 min @ 20°C | > 20 min @ 30°C | > 20 min @ 40°C | > 20 min @ 60°C | ≥ 20 min at the specified temperature | |
| Open timeFIP 5.2 | > 60 min @ 20°C | > 60 min @ 30°C | > 60 min @ 40°C | > 60 min @ 60°C | ≥ 60 min at the specified temperature | |
| Sag flowFIP 5.3 | < 30 mm @ 20°C | < 30 mm @ 30°C | < 30 mm @ 40°C | < 30 mm @ 60°C | ≤ 30 mm after 10 min at the specified temperature using Daniel's Gauge | |
| SqueezabilityFIP 5.4 | ≥ 3000 mm² @ 5°C | ≥ 3000 mm² @ 15°C | ≥ 3000 mm² @ 25°C | ≥ 3000 mm² @ 35°C | For a volume of 3140 mm³ mixed material with lower limit of temperature | |
| SqueezabilityFIP 5.4 | ≥ 3000 mm² @ 5°C | ≥ 3000 mm² @ 15°C | ≥ 3000 mm² @ 25°C | ≥ 3000 mm² @ 35°C | Squeezing load, kg 15 | Surface area mm² ≥ 3000 |
| Curing rate by Compressive strengthFIP 5.6 | > 20 MPa @ 12 hr @ 5°C > 40 MPa @ 1 day @ 5°C > 75 MPa @ 7 days @ 5°C | > 20 MPa @ 12 hr @ 15°C > 40 MPa @ 1 day @ 15°C > 75 MPa @ 7 days @ 15°C | > 20 MPa @ 12 hr @ 25°C > 40 MPa @ 1 day @ 25°C > 75 MPa @ 7 days @ 25°C | > 20 MPa @ 12 hr @ 35°C > 40 MPa @ 1 day @ 35°C > 75 MPa @ 7 days @ 35°C | Curing time | Compre- ssive strength at the lower limit of temperature |
| Curing rate by Compressive strengthFIP 5.6 | > 20 MPa @ 12 hr @ 5°C > 40 MPa @ 1 day @ 5°C > 75 MPa @ 7 days @ 5°C | > 20 MPa @ 12 hr @ 15°C > 40 MPa @ 1 day @ 15°C > 75 MPa @ 7 days @ 15°C | > 20 MPa @ 12 hr @ 25°C > 40 MPa @ 1 day @ 25°C > 75 MPa @ 7 days @ 25°C | > 20 MPa @ 12 hr @ 35°C > 40 MPa @ 1 day @ 35°C > 75 MPa @ 7 days @ 35°C | 12 hr 24 hr 7 days | ≥ 20 MPa ≥ 40 MPa ≥ 75 MPa |
| Compressive strengthFIP 5.12 | ≥ 60 MPa @ 24 hr @ 5°C ≥ 75 MPa @ 7 days @ 5°C | ≥ 60 MPa @ 24 hr @ 15°C ≥ 75 MPa @ 7 days @ 15°C | ≥ 60 MPa @ 24 hr @ 25°C ≥ 75 MPa @ 7 days @ 25°C | ≥ 60 MPa @ 24 hr @ 35°C ≥ 75 MPa @ 7 days @ 35°C | ≥ 60 MPa @ 24 hr ≥ 75 MPa @ 7 days | |
| Bonding of cured bonding agent and tensile bending strengthFIP 5.5/FIP 5.14 | Concrete failure (cured 1 day @ 5°C) | Concrete failure (cured 1 day @ 15°C) | Concrete failure (cured 1 day @ 25°C) | Concrete Failure (cured 1 day @ 35°C) | Bonding between two concrete surfaces should be concrete failure (application at the lower limit of temperature) | |
| Shear strengthFIP 5.15 after 7 days | > 12 Mpa @ 5°C | > 12 Mpa @ 15°C | > 12 Mpa @ 25°C | > 12 Mpa @ 35°C | ≥ 12 MPa after 7 days stored at the lower limit of temperature | |
| Heat resistance @ 50°C: FIP 5.10 after 7 days | Shear strength > 10 MPa | Minimum deflection temperature of 50°C (1.8 MPa load) ASTM D648 OR Shear strength to be ≥10 MPa (FIP 5.15) after 7 days @ 50°C | |||
|---|---|---|---|---|---|
| ShrinkageFIP 5.7 | < 0.4% @ 20°C | < 0.4% @ 30°C | < 0.4% @ 40°C | < 0.4% @ 60°C | ≤ 0.4% after 7 days at the upper limit of temperature |
| Modulus in comparisonFIP 5.13 after 7 days @ room temperature | > 8000 MPa | ≥ 8000 MPa @ room temperature | |||
| Shear modulusFIP 5.16 after 7 days | > 1500 MPa @ 5°C | > 1500 MPa @ 15°C | > 1500 MPa @ 25°C | > 1500 MPa @ 35°C | ≥ 1500 MPa after 7 days stored at the lower limit of temperature |
| Creep Pure comparison Pure shearFIP 5.8 | > 6000 MPa > 1000 MPa @ 20°C | > 6000 MPa > 1000 MPa @30°C | > 6000 MPa > 1000 MPa @ 40°C | > 6000 MPa > 1000 MPa @ 60°C | ≥ 6000 MPa @ 1 hr ≥ 1000 MPa @ 28 days |
| Water absorption and solubility in waterFIP 5.9 | < 0.5% < 0.1% | After 7 days curing at the upper limit of temperature. Specimen rods are submerged in water @ 60°C for 14 days Water absorption ≤ 0.5% Quantity dissolved in water ≤ 0.1% | |||
Standards and approvals
KingBond EP100PC complies with the International Federation for Prestressing (FIP) - Standard for acceptance tests and verification of epoxy bonding agents for segmental construction.
How to use
Surface preparation
The surface must be structurally sound, free from oil, grease and other forms of contamination. Roughen the substrate by grit blasting to accept KingBond EP100PC for improved mechanical key.
Mixing
KingBond EP100PC comprises two components, a resin base and a hardener, which are supplied preweighed in the correct proportions. Under no circumstances should part mixing be carried out.
When required for application, the two components should be mixed well until a uniform consistency and grey colour are obtained, this should be ideally carried out using a mechanical mixer.
WORKING CONDITIONS
The four grades and their respective application temperatures are:
- KingBond EP100PC 1; Fast set for application at ambient temperature between 5°C to 20°C.
- KingBond EP100PC 2; Medium set for application at ambient temperature between 15°C to 30°C.
- KingBond EP100PC 3; Slow set for application at ambient temperature between 25°C to 40°C.
- KingBond EP100PC 4; Very slow set for application at temperature between 35°C to 60°C.
Application
For bonding concrete segmental sections, an even layer of product should be applied to both surfaces within the adhesive open time using suitable spatula and ensuring that unbroken layer is achieved. Then the two segments are brought together under light pressure. Any excess paste which exudes from the joint should be removed and the joint finished to a neat finish. The assembled sections should be protected from movement until the resin is set.
Curing
Full mechanical and chemical properties are achieved after 7 days (please consult our Technical Department for details of curing times at other temperatures).
Cleaning
Clean uncured material with KingKrete solvent. Cured material can only be removed mechanically.
Coverage, packaging and storage
Coverage
Approximately 3.3 - 3.4 kg per m² at 2 mm thickness.
Yield
6 kg pack - 3.5 litres.
10 kg pack - 5.9 litres.
Packaging
KingBond EP100PC is available in 6 and 10 kg packs.
Storage
Shelf life is 1 year when stored under cover, out of direct sunlight and protected from extremes of temperature. Failure to comply with the recommended storage conditions may result in premature deterioration of the product or packaging. For specific storage advice consult KingKrete's Technical Services Department.
Health and safety
As with all chemical products, care should be taken during use and storage to avoid contact with eyes, mouth, skin and foodstuffs. Treat splashes to eyes and skin immediately. If accidentally ingested, seek medical attention. Reseal containers after use. Use in well ventilated areas and avoid inhalation.