Overview

KingBond EP100PC is high viscosity, solvent free epoxy adhesive.

Quickmasst SBA is a two components product. Components are black and white in colour, when mixed turn into a uniform grey colour paste that bonds segmental concrete.

Where to use

KingBond EP100PC is used for bonding segmental concrete bridges. Its high bonding characteristics will improve construction speed and provide structurally sound and water tight joints.

Why use it

  • Extremely high bond strength.
  • Relativelly fast curing.
  • Exhibit excellent squeezability.
  • Damp tolerant.
  • Available in four grades for different range of temperature application.

Technical properties

Colour: FIP 5.11 Base
Hardener
Mixed
White
Black
Grey similar to adjoining concrete
Mixed density1.70 ± 0.1 g/cm³
KingKreteSBA 1SBA 2SBA 3SBA 4FIP Requirements
Application
temperature
5 - 20°C15 - 30°C25 - 40°C35 - 60°C
Pot lifeFIP 5.1> 20 min @
20°C
> 20 min @
30°C
> 20 min @
40°C
> 20 min @
60°C
≥ 20 min at the
specified temperature
Open timeFIP 5.2> 60 min @
20°C
> 60 min @
30°C
> 60 min @
40°C
> 60 min @
60°C
≥ 60 min at the
specified temperature
Sag flowFIP 5.3< 30 mm @
20°C
< 30 mm @
30°C
< 30 mm @
40°C
< 30 mm @
60°C
≤ 30 mm after 10 min at
the specified
temperature using
Daniel's Gauge
SqueezabilityFIP 5.4≥ 3000 mm² @
5°C
≥ 3000 mm² @
15°C
≥ 3000 mm² @ 25°C≥ 3000 mm² @
35°C
For a volume of 3140
mm³ mixed material
with lower limit of
temperature
SqueezabilityFIP 5.4≥ 3000 mm² @
5°C
≥ 3000 mm² @
15°C
≥ 3000 mm² @ 25°C≥ 3000 mm² @
35°C
Squeezing
load,
kg 15
Surface
area mm²
≥ 3000
Curing rate by
Compressive
strengthFIP 5.6
> 20 MPa @ 12
hr @ 5°C
> 40 MPa @ 1
day @ 5°C
> 75 MPa @ 7
days @ 5°C
> 20 MPa @ 12
hr @ 15°C
> 40 MPa @ 1
day @ 15°C
> 75 MPa @ 7
days @ 15°C
> 20 MPa @ 12
hr @ 25°C
> 40 MPa @ 1
day @ 25°C
> 75 MPa @ 7
days @ 25°C
> 20 MPa @
12 hr @ 35°C
> 40 MPa @ 1
day @ 35°C
> 75 MPa @ 7
days @ 35°C
Curing
time
Compre-
ssive
strength at
the lower
limit of
temperature
Curing rate by
Compressive
strengthFIP 5.6
> 20 MPa @ 12
hr @ 5°C
> 40 MPa @ 1
day @ 5°C
> 75 MPa @ 7
days @ 5°C
> 20 MPa @ 12
hr @ 15°C
> 40 MPa @ 1
day @ 15°C
> 75 MPa @ 7
days @ 15°C
> 20 MPa @ 12
hr @ 25°C
> 40 MPa @ 1
day @ 25°C
> 75 MPa @ 7
days @ 25°C
> 20 MPa @
12 hr @ 35°C
> 40 MPa @ 1
day @ 35°C
> 75 MPa @ 7
days @ 35°C
12 hr
24 hr
7 days
≥ 20 MPa
≥ 40 MPa
≥ 75 MPa
Compressive
strengthFIP 5.12
≥ 60 MPa @ 24
hr @ 5°C
≥ 75 MPa @ 7
days @ 5°C
≥ 60 MPa @ 24
hr @ 15°C
≥ 75 MPa @ 7
days @ 15°C
≥ 60 MPa @ 24
hr @ 25°C
≥ 75 MPa @ 7
days @ 25°C
≥ 60 MPa @
24 hr @ 35°C
≥ 75 MPa @ 7
days @ 35°C
≥ 60 MPa @ 24 hr
≥ 75 MPa @ 7 days
Bonding of
cured bonding
agent and
tensile bending
strengthFIP 5.5/FIP 5.14
Concrete failure
(cured 1 day @
5°C)
Concrete failure
(cured 1 day @
15°C)
Concrete failure
(cured 1 day @
25°C)
Concrete
Failure (cured
1 day @ 35°C)
Bonding between two
concrete surfaces should
be concrete failure
(application at the lower
limit of temperature)
Shear strengthFIP 5.15
after 7 days
> 12 Mpa
@ 5°C
> 12 Mpa
@ 15°C
> 12 Mpa
@ 25°C
> 12 Mpa
@ 35°C
≥ 12 MPa after 7 days
stored at the lower limit of
temperature
Heat resistance @
50°C: FIP 5.10
after 7 days
Shear
strength
> 10 MPa
Minimum deflection temperature
of 50°C (1.8 MPa load) ASTM
D648 OR Shear strength to be
≥10 MPa (FIP 5.15) after 7 days
@ 50°C
ShrinkageFIP 5.7< 0.4% @
20°C
< 0.4% @
30°C
< 0.4% @
40°C
< 0.4% @
60°C
≤ 0.4% after 7 days at the upper limit of temperature
Modulus in
comparisonFIP 5.13
after 7 days
@ room
temperature
> 8000 MPa≥ 8000 MPa
@ room temperature
Shear modulusFIP 5.16
after 7 days
> 1500 MPa
@ 5°C
> 1500 MPa
@ 15°C
> 1500 MPa
@ 25°C
> 1500 MPa
@ 35°C
≥ 1500 MPa after 7 days stored
at the lower limit of temperature
Creep
Pure comparison
Pure shearFIP 5.8
> 6000 MPa
> 1000 MPa
@ 20°C
> 6000 MPa
> 1000 MPa
@30°C
> 6000 MPa
> 1000 MPa
@ 40°C
> 6000 MPa
> 1000 MPa
@ 60°C
≥ 6000 MPa @ 1 hr
≥ 1000 MPa @ 28 days
Water absorption
and solubility in
waterFIP 5.9
< 0.5%
< 0.1%
After 7 days curing at the upper
limit of temperature.
Specimen rods are submerged in
water @ 60°C for 14 days
Water absorption ≤ 0.5%
Quantity dissolved in water
≤ 0.1%

Standards and approvals

KingBond EP100PC complies with the International Federation for Prestressing (FIP) - Standard for acceptance tests and verification of epoxy bonding agents for segmental construction.

How to use

Surface preparation

The surface must be structurally sound, free from oil, grease and other forms of contamination. Roughen the substrate by grit blasting to accept KingBond EP100PC for improved mechanical key.

Mixing

KingBond EP100PC comprises two components, a resin base and a hardener, which are supplied preweighed in the correct proportions. Under no circumstances should part mixing be carried out.

When required for application, the two components should be mixed well until a uniform consistency and grey colour are obtained, this should be ideally carried out using a mechanical mixer.

WORKING CONDITIONS

The four grades and their respective application temperatures are:

  • KingBond EP100PC 1; Fast set for application at ambient temperature between 5°C to 20°C.
  • KingBond EP100PC 2; Medium set for application at ambient temperature between 15°C to 30°C.
  • KingBond EP100PC 3; Slow set for application at ambient temperature between 25°C to 40°C.
  • KingBond EP100PC 4; Very slow set for application at temperature between 35°C to 60°C.
Application

For bonding concrete segmental sections, an even layer of product should be applied to both surfaces within the adhesive open time using suitable spatula and ensuring that unbroken layer is achieved. Then the two segments are brought together under light pressure. Any excess paste which exudes from the joint should be removed and the joint finished to a neat finish. The assembled sections should be protected from movement until the resin is set.

Curing

Full mechanical and chemical properties are achieved after 7 days (please consult our Technical Department for details of curing times at other temperatures).

Cleaning

Clean uncured material with KingKrete solvent. Cured material can only be removed mechanically.

Coverage, packaging and storage

Coverage

Approximately 3.3 - 3.4 kg per m² at 2 mm thickness.

Yield

6 kg pack - 3.5 litres.

10 kg pack - 5.9 litres.

Packaging

KingBond EP100PC is available in 6 and 10 kg packs.

Storage

Shelf life is 1 year when stored under cover, out of direct sunlight and protected from extremes of temperature. Failure to comply with the recommended storage conditions may result in premature deterioration of the product or packaging. For specific storage advice consult KingKrete's Technical Services Department.

Health and safety

As with all chemical products, care should be taken during use and storage to avoid contact with eyes, mouth, skin and foodstuffs. Treat splashes to eyes and skin immediately. If accidentally ingested, seek medical attention. Reseal containers after use. Use in well ventilated areas and avoid inhalation.

Request the safety data sheet