🌍 🌐 English
Tile & Stone Adhesives and Grouts

KingFix EPF500®

Three component high performance solvent free epoxy ceramic tile and stone adhesive and grout specially designed to grout narrow joints between tiles.

SpecWorld has the Spec Pack, CSI specification and drawings for registered specifiers.

Compressive strength ISO 13007-4, 4.1.4
≥ 60 MPa
Flexural strength ISO 13007-4, 4.1.3
≥ 30 MPa
Shear adhesion strength ISO 13007-2, 4.3.4
≥ 3.0 MPa
Abrasion resistance ISO 13007-4, 4.4
≤ 200 mm³

Overview

KingFix EPF500 is a chemical and abrasion resistant solvent free tile adhesive and grout ideal for demanding surface exposure or high traffic areas. KingFix EPF500 may be applied in conditions where the substrate is humid.

KingFix EPF500 is suitable for all types of ceramic tiles and stone in internal, external and submerged conditions. KingFix EPF500 is a three component system consisting of a resin base, hardener and select fillers.

Where to use

KingFix EPF500 is suitable for indoor, outdoor and submerged use in application areas such as:

  • Grouting narrow joints (i.e. less than 3 mm width) between all types of tiles.
  • Swimming Pools.
  • Laboratories.
  • Kitchens.
  • Dairy Industries.
  • Meet Poultry and Food Processing Plants.
  • Hospitals.
  • Abattoirs.
  • Pharmaceutical Plants.

Why use it

  • Super fine formation for ease of application inside narrow joints.
  • Application on humid substrates.
  • High chemical resistance.
  • High abrasion resistance.
  • Highly deformable.
  • High slip resistance, for demanding vertical tiling.
  • High bond strength.
  • Mould & stain impermeable.
  • Water impermeable.
  • Fast setting.
  • Suitable for all ceramic tiles and stones.
  • Suitable for internal, external and submerged conditions.
  • Available in a wide range of colours.

Technical properties

Pot life80 - 110 min @ 25°C
50 - 80 min @ 35°C
Mixed density1.65 ± 0.10 g/cm³
Open time, tensile adhesion
strength: ISO 13007-2, 4.1
≥ 4.0 MPa
(after 20 min)
Shear adhesion strengthISO 13007-2, 4.3.4≥ 3.0 MPa
Shear adhesion strengthISO 13007-2, 4.3.5≥ 3.0 MPa
(after water immersion)
Shear adhesion strengthISO 13007-2, 4.3.8≥ 3.0 MPa
(after thermal shock)
Abrasion resistanceISO 13007-4, 4.4≤ 200 mm³
Water absorptionISO 13007-4, 4.2< 0.1 g
(after 240 min)
ShrinkageISO 13007-4, 4.3< 1.5 mm/m
Compressive strengthISO 13007-4, 4.1.4≥ 60 MPa
Flexural strengthISO 13007-4, 4.1.3≥ 30 MPa
Service temperature- 20 to 100°C
Initial setting timeASTM C3087 hr @ 25°C
Full chemical cure7 days
Minimum application
temperature
5°C
VOCASTM D2369< 50 g/ltr
(complies with LEED)

As a tile grout

  • KingFix EPF500 complies with ISO 13007-3 and BS EN 13888 specifications, Class RG.
  • KingFix EPF500 complies with ANSI A118.3 as a water cleanable tile setting and grouting epoxy.

Standards and approvals

As a tile adhesive

  • KingFix EPF500 complies with ISO 13007-1 and BS EN 12004 specifications, Class R2T.

How to use

Surface preparation

1)As a tile adhesive

  • Substrates should be clean and free from dust or any contamination.
  • Steel surfaces shall be free from rust or other contaminants, ideally grit blasted to a near white finish in accordance to Swedish standards SA 2 ½.
  • It is recommended that surfaces are in dry condition before tiling. However, KingFix EPF500 can be applied on humid substrates.

2)As a tile grout

  • Joint surfaces should clean and free from dust or any contamination.
  • Joints should be cleaned to the full thickness of the tile or to a minimum depth of 2/3 of the tile thickness.

Joints should be dry before grout filling.

Mixing

To ensure proper mixing, a mechanically powered mixer or drill fitted with a suitable paddle should be used. Stir the base and the hardener individually to disperse any settlement.

The entire contents of the base and hardener should be poured into a suitable size container and mixed mechanically for 2 minutes. Add the filler to the base/ hardener mixture and mix for another 3 minutes until a uniform colour is achieved.

PLACING AND FINISHING

1)As a tile adhesive

Spread the mixed adhesive to the substrate using a notched trowel. Apply with pressure a 1 to 2 mm coat with pressure using the flat face of the notched trowel onto the substrate.

Comb diagonally additional mixed adhesive up to a 3 mm total maximum thickness with the notched side of the notched trowel. Do not apply large areas of adhesive that cannot be covered within the open wet time of the adhesive.

2)As a tile grout

Use a masking tape on joint edges to protect tiles. Fill the mixed grout into the joints using rubber trowel or by using hand operated gun and cartridges.

Excess grout should be cleaned with a proper wet cloth within the material pot life.

CHEMICAL RESISTANCE

ISO 13007-2:2010 after submersion in the following chemicals:
After 7 days full immersionAfter 28 days full immersion
Ammonia 10% - LiquidR
Citric Acid 10%R
Diesel fuel
Hydrochloric Acid 10%R
KeroseneR
Lactic Acid 10%R
Nitric Acid 10%R
Phosphoric Acid 37%RS
Potassium hydroxide 50%R
Sulfuric Acid 10%R
Vinegar 5%R
Water - DistilledR
Chlorinated waterRS
Water - FreshR
Water - Sea, SaltR
XyleneR-

Note: Slight discoloration may occur without affecting the performance.

WORKING CONDITIONS

KingFix EPF500 should not be applied at temperatures below 5°C.

Cleaning

Cleaning should be commenced immediately before the grout reaches initial setting. After initial set, product may be removed either by using solvent or by mechanical means but with great difficulty.

Coverage, packaging and storage

Yield

When used as a tile adhesive, each 6 kg pack shall cover 3.6 m² at 1 mm thickness.

When used as tile grout The approximate yield of the grout can be calculated as per the following equation:

Yield (m²/kg) = 6.0

WD (0.02 + 1 + 1 )

L H

Where:

L: Tile length (cm)

H: Tile width (cm)

D: Average joint depth (mm)

W:Average joint width (mm)

Note: Grout yield is subject to ± 15% tolerance.

Packaging

KingFix EPF500 is available in 6 kg packs (3.6 ltr) and 12 kg packs (7.3 ltr).

Storage

Shelf life is 1 year when stored under cover, out of direct sunlight and protected from extremes of temperature. Failure to comply with the recommended storage conditions may result in premature deterioration of the product or packaging. For specific storage advice consult KingKrete's Technical Services Department.

Health and safety

As with all chemical products, care should be taken during use and storage to avoid contact with eyes, mouth, skin and foodstuffs. Treat splashes to eyes and skin immediately. If accidentally ingested, seek medical attention. Reseal containers after use. Use in well ventilated areas and avoid inhalation.

Request the safety data sheet