KingProof PUB100®
One component, polyurethane-bitumen liquid membrane for flashing, waterproofing and protection.
SpecWorld has the Spec Pack, CSI specification and drawings for registered specifiers.
- Tensile strength ASTM D412
- ≥ 3.5 MPa
- Adhesion to concrete ASTM D4541
- ≥ 1.0 MPa
- Elongation at break ASTM D412
- ≥ 470%
- Shore A Hardness ASTM D2240
- 25 ± 5
Overview
KingProof PUB100 is a quick-curing, one component, thixotropic, bitumen-extended polyurethane fluid based on pure elastomeric hydrophobic polyurethane resin and is extended with chemically polymerised virgin bitumen.
It produces a hydrophobic, elastic membrane with very strong adhesion to most types of substrate, as well as bituminous, and excellent mechanical and chemical resistance properties. It is ideal for application on vertical surfaces: no running, no blubbing.
Where to use
Waterproofing and protection of
- Foundations.
- Wet areas (Bathrooms, kitchens, etc.).
- Shaded roofs (i.e. unexposed to UV).
- Vertical and horizontal substrates.
- Cementitious substrates.
- Irrigation channels.
- Gypsum and cement boards.
- Asphalt membranes (for repair also).
Why use it
- Fast curing.
- Excellent adhesion to almost any surface.
- Excellent thermal resistance and service temperatures.
- Cold Resistance: the film remains elastic down to minus 40°C.
- Excellent mechanical properties, high elongation, high tensile and tear strength, high abrasion resistance.
- Thixotropic consistency, easily applied on vertical surface and complex shapes without running or bubbling.
- Excellent chemical resistance.
Technical properties
Values @ 23°C & 55% RH
| Colour | Black |
|---|---|
| Specific gravity | 1.20 ± 0.05 |
| Tack free time | 8 – 10 hr |
| Recoatable time | 12 - 24 hr |
| Light pedestrian traffic time | 48 hr |
| Final cure | 7 days |
| Shore A HardnessASTM D2240 | 25 ± 5 |
| Tensile strengthASTM D412 | ≥ 3.5 MPa |
| Elongation at breakASTM D412 | ≥ 470% |
| Adhesion to concreteASTM D4541 | ≥ 1.0 MPa |
| Crack bridgingASTM C1305 | Pass |
| Hydrolysis resistance (KOH 8% 10 days) | Pass |
| Service temperature | -40 to 80°C |
Standards and approvals
KingProof PUB100 complies with ASTM C836.
How to use
Surface preparation
The surface should be clean, dry, sound and free from oil, grease and wax contamination.
Cement laitance, loose particles, mould release agent or curing membranes must be removed.
Fill surfaces irregularities with a suitable product. Maximum moisture content should not exceed 5%. New concrete structures need to dry for at least 28 days.
Important: Do not wash surface with water.
Priming
It is recommended to prime all kinds of substrates using KingProof Primer PW. The primer is designed to significantly improve the adhesion between KingProof PUB100 and all kind of non-porous substrates such as steel, glassy tiles and aluminum. It will also stabilize and fortify weak and porous substrates prior to the application of KingProof PUB100.
KingProof Primer PW should be applied using a brush or roller at a rate of 0.16 liters/m2 to achieve around 70 - 75 micron DFT.
Leave the primer to cure for 24 hours before the application of KingProof PUB100.
Application
For spraying with airless spray machine, KingProof PUB100 can be diluted by 5 - 10% using KINGKRETE Solvent PU (consult KINGKRETE's technical department for further details). For any mixing done on site, low speed (300 rpm) mixer or electric drill should be used.Apply the material with roller or brush. Apply at least two coats. Do not leave more than 24 hours between coats.
Cleaning
All tools should be cleaned after finishing with paper towels and then wipe by using KINGKRETE Solvent PU. Do not try to clean rollers.
Limitations and notes
Limitations
- KingProof PUB100 should not be applied over unsound substrates.
- KingProof PUB100 is not recommended for areas exposed to UV rays.
Notes
It is always recommended to test the adhesion between the substrates and KingProof PUB100 on small area onsite prior to proceeding the works in order to ensure that the substrate is well prepared and compatible with the product.
Coverage, packaging and storage
Consumption
- First coat: 0.7 - 0.9 kg/m².
- Second coat: 0.7 - 0.9 kg/m².
- Total consumption: 1.4 - 1.8 kg/m² to give 1.0 - 1.3 mm dry film thickness.
Packaging
KingProof PUB100 is available in 5 and 20 kg packs.
Storage
Shelf life is 1 year when stored under cover, out of direct sunlight and protected from extremes of temperature.
Failure to comply with the recommended storage conditions may result in premature deterioration of
the product or packaging. For specific storage advice consult KingKrete's Technical Services Department.
Health and safety
As with all chemical products, care should be taken during use and storage to avoid contact with eyes, mouth, skin and foodstuffs. Treat splashes to eyes
and skin immediately. If accidentally ingested, seek
medical attention. Reseal containers after use. Use in well ventilated areas and avoid inhalation.