KingProof HR25®

Heat resistant backing rod for hot sealant.

SpecWorld has the Spec Pack, CSI specification and drawings for registered specifiers.

Tensile strength
400 KPA
Elongation at break
22%
Density
138 kg/m³

Overview

KingProof HR25 is a specialized cord made from cellulose wadding for use in the construction industry. The cord provides a natural barrier onto which hot sealants can be poured or extruded to make expansion joints.

Where to use

  • Expansion joint sealer in runways, motorways, cargo areas.
  • All concrete slab construction.

Why use it

  • Does not melt.
  • Allows hot sealants to cool easily.
  • Prevents seepage and waste.
  • Does not rot or disintegrate.
  • Easy to install.
  • Economical.

TEMPERATURE STABILITY

-40°C to +200°C.

Technical properties

Compressive strength
10%
25%
50%
24 KPA
45 KPA
112 KPA
Tensile strength400 KPA
Elongation at break22%
Density138 kg/m³
Operating temperature-40 – 200°C

Sealant

KingProof HR25

How to use

Method of use

KingProof HR25 diameter should be greater than the joint width by 20% to 25%. This will insure that it is held in position and the joint width/depth ratio is maintained. KingProof HR25 cords may be installed by pushing to fit into joints.

ESTIMATING

KingProof HR25 cords are available in the following diameters (6, 10, 15, 20, 25, 30, 40 and 50 mm).

Coverage, packaging and storage

Storage

Shelf life is 1 year when stored under cover, out of direct sunlight and protected from extremes of temperature.

Failure to comply with the recommended storage conditions may result in premature deterioration of the product or packaging. For specific storage advice consult KingKrete's Technical Services Department.

Health and safety

As with all chemical products, care should be taken during use and storage to avoid contact with eyes, mouth, skin and foodstuffs. Treat splashes to eyes

and skin immediately. If accidentally ingested, seek

medical attention. Reseal containers after use. Use in well ventilated areas and avoid inhalation.

Request the safety data sheet