KingProof A100®
Elastomeric acrylic waterproof coating for roofs.
SpecWorld has the Spec Pack, CSI specification and drawings for registered specifiers.
- Tensile Strength ASTM D412, Die C
- ≥ 1.3 MPa @ 7 days
- Adhesion Strength ASTM D4541
- ≥ 1.5 MPa @ 7 days
- Specific Gravity
- 1.25 ± 0.05
Overview
A KingProof A100 is an acrylic based highly flexible, high performance elastomeric, waterproof coating for roofs and walls.
KingProof A100 is suitable for application on various construction substrates such as concrete, masonry, plaster and terrazzo tiles.
KingProof A100 is available in variety of colours and ideally suited for external applications.
Where to use
KingProof A100 is designed for use as
- Waterproof coating for sloped roofs and vertical walls.
- Waterproof coating over existing terrazzo tiles.
- Waterproof and protective coating over roof polyurethane foam.
- Waterproofing and protection over bituminous waterproofing membranes and coatings.
Why use it
- Elastomeric.
- Single component, easy to apply.
- Available in different colours.
- UV stable and resistant.
- Will not support fungus growth.
- Easy maintenance.
Technical properties
Values @ 25°C
| Appearance | Thick liquid |
|---|---|
| Colour | White, Grey, Beige (Various) |
| Overcoating Time | Minimum 4 hr |
| Solid Content | |
| By Weight | 60 ± 2% |
| By Volume | 50 ± 2% |
| Specific Gravity | 1.25 ± 0.05 |
| Permeability to water: EN 1062-3 | < 0.1 kg/m².h⁰·⁵ |
| Adhesion Strength ASTM D4541 | ≥ 1.5 MPa @ 7 days |
| Tensile Strength ASTM D412, Die C | ≥ 1.3 MPa @ 7 days |
| ElongationASTM D412 | > 350% @ 2 mm dry thickness |
| Minimum application temperature | 5°C |
| VOC | < 50 g/ltr |
The first coat of KingProof A100 should be applied at the rate of 2.5 m2/litre and allowed to cure for 4 - 12 hours (depending in the ambient temperature) before being overcoated with the second coat.
The second coat should be applied perpendicular to the first coat at the same rate above, and allowed to cure.
For heavy pedestrian traffic, it is recommended to use fibreglass scrim reinforcement, embedded firmly in the second coat while wet, and a third coat should be applied.
Note: KingProof A100 should not be applied at ambient temperatures below 5°C and dropping. KingProof A100 should not be applied on surfaces expected to suffer form rising dampness or relative humidity greater than 75%.
How to use
Surface preparation
Surfaces to receive KingProof A100 should be clean, sound, and free from oil, grease, dirt and loose particles. Substrate should be dry, with no standing water. Spalled surfaces, cracks and defected concrete should be repaired. New concrete substrate should be at least 14 days old.
Application
KingProof A100 can be applied by brush, roll, or airless spray machine. Porous surfaces should primed with KingProof A100 primer at the rate of 5 m²/litre and allowed to dry before applying the first coat.
Cleaning
All tools should be washed and cleaned immediately after use with clean water.
Coverage, packaging and storage
Coverage
Approximately 0.40 litre/m² per coat (0.50 kg/m²) toachieve 200 micron dry film thickness.
Packaging
KingProof A100 is available in 16 litres (20 kg), 18 litres (22.5 kg) and 120 litres (150 kg) packs.
KingProof A100 Primer is available in 5 litres (5 kg) and 25 litres (25 kg) packs.
Storage
Shelf life is 1 year when stored under cover, out of direct sunlight and protected from extremes of temperature.
Failure to comply with the recommended storage conditions may result in premature deterioration of the product or packaging. For specific storage advice consult KingKrete's Technical Services Department.
Health and safety
As with all chemical products, care should be taken during use and storage to avoid contact with eyes, mouth, skin and foodstuffs. Treat splashes to eyes and skin immediately. If accidentally ingested, seek medical attention. Reseal containers after use. Use in well ventilated areas and avoid inhalation.