KingCoat A®
One component water based acrylic elastomeric protective anti carbonation coating system.
SpecWorld has the Spec Pack, CSI specification and drawings for registered specifiers.
- Tensile strength ASTM D412
- ≥ 1.5 MPa @ 7 days
- Elongation at break ASTM D412
- ≥ 350% @ 7 days
- Density
- 1.35 ± 0.05 g/cm³
Overview
KingCoat A is a high build elastomeric, microporous coating exhibiting excellent resistance to attack from carbon dioxide, airborne chlorides and acid rain, with exceptional weathering resistance.
KingCoat A has excellent crack bridging properties, yet provides a smooth protective, decorative coating for concrete and other masonry surfaces. For effective anti-carbonation protection a two-coat treatment is recommended after the application of the silane siloxane based impregnating primer. The product is formulated to give a tough flexible and coloured coating which will give a waterproofing coating to a wide variety of substrates. A textured finish may be obtained if required.
Where to use
- Bridge abutments.
- External concrete surfaces of storage tank and masonry surfaces.
- Multistory building and villas.
- Where a high external tough coating is required.
- Concrete cladding.
Why use it
- High build elastomeric, microporous coating.
- Excellent resistance to carbon dioxide, airborne, chlorides and water borne.
- Exceptional weathering resistance.
- Excellent crack bridging properties.
- Protective and decorative coating.
- Excellent waterproofing characteristics.
Technical properties
| Colour | White, grey, and can be available in different colours |
|---|---|
| Density | 1.35 ± 0.05 g/cm³ |
| Solid content By weight By volume | 64 ± 2% 53 ± 2% |
| Touch dry time | 30 - 60 min @ 25°C |
| Overcoating time between consecutive coats of KingCoat A* | 2 hr @ 35°C 4 hr @ 25°C |
| Application temperature | 5 to 38°C |
| Elongation at breakASTM D412 | ≥ 350% @ 7 days |
| Tensile strengthASTM D412 | ≥ 1.5 MPa @ 7 days |
| Carbonation depth TM:NT Build 372:1991-02 700 hr @ severe conditions of humidity & 20% CO₂ | No penetration in coated sample 0.7 mm penetration in control |
| Chloride ion diffusion coefficient:TM:NT Build 492:1999-11 | 7.3 x 10 ⁻¹⁵ m²/sec |
| Reduction in chloride Ion penetration in severe environment with focused applied voltage as perASTM C1202 | 98% |
| Surface burning characteristicsASTM E84 Flame spread index (FSI) Smoke development index (SDI) | 10 10 |
| VOC | < 50 g/ltr |
*If more than one coat is needed.
Any traces of mould or algae must be removed and the area treated with a suitable anti-fungicide or bleach solution. KingCoat A can be applied over green dry concrete, as long as KingCoat Primer is used.
Standards and approvals
KingCoat A complies with the requirements of EN 1504-2 Surface Protection Systems Principles 1.3, 2.2 and 8.2.
How to use
Surface preparation
The substrate should be sound clean and free from dust and all loose or flaking material. All holes and deep cracks should be filled with a suitable filler. All traces of oil, grease, chemical contaminants and extraneous matter should be removed.
Priming
KingCoat A Primer is a ready for use, single component primer based on a silane/siloxane and an acrylic resin providing protection from rebar corrosion, efflorescence, freeze-thaw damage, water penetration, oil penetration, mold and mildew.
KingCoat A Primer should only be applied over clean and sound substrates that are free from oil, grease and curing compounds. KingCoat A primer should be applied only on dry, clean, sound and free from oil, grease, curing compound substrates. KingCoat A primer is applied at a rate between 0.1 - 0.2 litre/m2 depends on the porosity of the substrates. It is important to wait for a minimum of 12 hours before the application of KingCoat A.
KingCoat A Primer will not only improve the adhesion of KingCoat A on the substrates, but also it will reduce the CO2 permeability and capillary water absorption of the system. The application of KingCoat A Primer becomes more important when the system is applied over weak substrates such as cement board or non-structural repair mortar.
Mixing
Stir KingCoat A thoroughly prior to use.
Application
KingCoat A can be applied normally at temperatures between 5°C and 38°C. Apply evenly with roller, brush or airless spray. A one coat or two-coat system may be used. Two coats should always be used on dark, absorbent and heavily textured surfaces and when full carbonation protection is required. Porous, rough and irregular surfaces will reduce coverage rates.
Cleaning
Tools and equipment can be cleaned with water.
Coverage, packaging and storage
Coverage
KingCoat A: 0.38 litre/m² per coat to achieve 200 microns dry film thickness.
KingCoat Primer: 0.1 - 0.2 litre/m², depending on the substrate porosity.
| Performance characteristics | EN 1504-2 requirements | Measured value |
|---|---|---|
| Permeability to CO₂EN 1062-6 | SD > 50 m | > 60 m |
| Permeability to water vapour: ISO 7783-1ISO 7783-2 | Class I: SD < 5 m (Permeable) Class II: 5 ≤ SD ≤ 50 m Class III: SD > 50 m (Not Permeable) | SD ≤ 0.5 m (Permeable to water vapour) |
| Capillary water absorptionEN 1063-3 | < 0.1 kg/m².h ⁰·⁵ | ≤ 0.03 kg/ m².h⁰·⁵ |
| Adhesion strength: EN 1542 | ≥ 1.5 MPa | ≥ 2.0 MPa (Flexible systems with trafficking) |
Packaging
KingCoat A is available in 5, 18 and 120 litre drums. KingCoat A primer is available in 5, 20 and 200 litre drums.
Storage
Shelf life is 1 year when stored under cover, out of direct sunlight and protected from extremes of temperature. Failure to comply with the recommended storage conditions may result in premature deterioration of the product or packaging. For specific storage advice consult KingKrete's Technical Services Department.
Health and safety
As with all chemical products, care should be taken during use and storage to avoid contact with eyes, mouth, skin and foodstuffs. Treat splashes to eyes and skin immediately. If accidentally ingested, seek medical attention. Reseal containers after use. Use in well ventilated areas and avoid inhalation.