One component water based acrylic elastomeric protective anti carbonation coating system.

Density
1.35 ± 0.05 g/cm3
Touch dry time
30 - 60 min @ 25oC
Coverage
KingCoat A: 0.38 li…
Packaging
Drum
Standards
3 cited
ASTM C1202 · ASTM D412

Overview

KingCoat A is a high build elastomeric, microporous coating exhibiting excellent resistance to attack from carbon dioxide, airborne chlorides and acid rain, with exceptional weathering resistance. KingCoat A has excellent crack bridging properties, yet provides a smooth protective, decorative coating for concrete and other masonry surfaces. For effective anti- carbonation protection a two-coat treatment is recommended after the application of the silane siloxane based impregnating primer. The product is formulated to give a tough flexible and coloured coating which will give a waterproofing coating to a wide variety of substrates. A textured finish may be obtained if required.

Applications

  • Bridge abutments
  • External concrete surfaces of storage tank and masonry surfaces
  • Multistory building and villas
  • Where a high external tough coating is required
  • Concrete cladding

Advantages

  • High build elastomeric, microporous coating
  • Excellent resistance to carbon dioxide, airborne, chlorides and water borne
  • Exceptional weathering resistance
  • Excellent crack bridging properties
  • Protective and decorative coating
  • Excellent waterproofing characteristics
  • STANDARDS KingCoat A complies with the requirements of EN 1504-2 Surface Protection Systems Principles 1.3, 2.2 and 8.2

Technical Properties

PropertyValueStandard
ColourWhite, grey, and can be available in different colours
Density1.35 ± 0.05 g/cm3
Solid contentBy weight By 64 ± 2% 53 ± 2% volume
Touch dry time30 - 60 min @ 25oC
Overcoating time between2 hr @ 35oC 4 hr @ 25oC consecutive coats of
KingCoat A*
Application temperature5 to 38oC
Elongation at breakASTM ≥ 350% @ 7 days D412
Tensile strength≥ 1.5 MPa @ 7 daysASTM D412
Carbonation depthTM:NT No penetration in coated
Build 3721991-02 700 hr @ sample 0.7 mm penetration severe conditions of humidity in control & 20% CO2
Chloride ion diffusion7.3 x 10 -15 m2/sec
coefficientTM:NT Build
4921999-11
Reduction in chloride Ion98% penetration in severe environment with focused applied voltage as perASTM C1202
Surface burning10 10 characteristicsASTM E84
Flame spread index (FSI)Smoke development index
(SDI)
VOC< 50 g/ltr *If more than one coat is needed. Any traces of mould or algae must be removed and the area treated with a suitable anti-fungicide or bleach solution. KingCoat A can be applied over green dry concrete, as long as KingCoat Primer is used.

Standards & Approvals

ASTM
ASTM C1202
ASTM
ASTM D412
ASTM
ASTM E84
ISO
ISO 9001 · 14001 · 45001Quality & EHS

Usage & Packaging

Packaging

KingCoat A is available in 5, 18 and 120 litre drums. KingCoat A primer is available in 5, 20 and 200 litre drums.

Coverage

KingCoat A: 0.38 litre/m2 per coat to achieve 200 microns dry film thickness. KingCoat Primer: 0.1 - 0.2 litre/m2, depending on the substrate porosity. anti carbonation coating system. Performance EN 1504-2 Measured characteristics requirements value Perm

Storage

Shelf life is 1 year when stored under cover, out of direct sunlight and protected from extremes of temperature