- Tensile strength ASTM D412
- 1.0 ± 0.1 MPa
- Elongation ASTM D412
- > 400%
- Shore A hardness ASTM D2240
- 20 ± 5
Overview
KingSeal SN100 is a one-part Low Modulus Neutral Cure Silicone Sealant, which cures on exposure to moisture vapour to form an elastic silicone rubber.
Where to use
Recommended for use in many forms of construction including glass wall assemblies, perimeter seals on curtain walling, perimeter sealing of polyester powder coated frames and glazing of windows in swimming pool buildings. KingSeal SN100 is fungicide.
Technical properties
Values @ 25°C, 50%RH
| Consistency | Soft paste |
|---|---|
| ElongationASTM D412 | > 400% |
| Specific gravity Transparent Coloured | 1.00 ± 0.05 1.25 ± 0.05 |
| UV resistance | Very good |
| Skinning time | 15 ± 5 min |
| Shore A hardnessASTM D2240 | 20 ± 5 |
| Tensile strengthASTM D412 | 1.0 ± 0.1 MPa |
| Service temperature | -20 up to 80°C |
| Application temperature | 5 to 50°C |
| Chemical resistance | Resistant to most alkalis and dilute acids. Organic solvents may cause the sealant to swell and lose adhesion, but do not directly dissolve the sealant |
| Service life | +25 years |
| Curing rate | 2 - 3 mm/day |
| Colours | White, black, grey, mahogany, translucent & anthracite |
| VOC | < 30 g/ltr |
Standards and approvals
KingSeal SN100 complies with BS EN ISO11600 F/G 20 LM, BS5889, Type A:1989 and BS6920, Part 1:1990.
How to use
Method of use
Joint Preparation
The joint surfaces must be clean, dry and free from all contamination. Primers may be required on some substrates.
Joint Backing
Where applicable, appropriate joint filler e.g. closed cell polyethylene foam, should be used to provide the correct joint depth.
Application
KingSeal SN100 is supplied in cartridges and can be applied into the joint using a skeleton gun. Cut-off the cartridge top then the nozzle to required size.
Attach the nozzle to the cartridge. Extrude the sealant firmly against the joint surfaces to ensure complete contact. Tool the sealant into the joint to compact and achieve a good surface finish. Tool within 5 minutes from the application of the sealant.
It is recommended to use masking tape on each side of the joint to maintain a clean and uniform joint sides. Remove the masking tape directly after tooling the sealant.
Coverage, packaging and storage
Packaging
25 x 280 ml plastic cartridges. Polyethylene nozzles are included in each box.
SEALANT QUANTITY ESTIMATOR
| Joint size mm | Meters per Litre |
|---|---|
| 6 x 6 | 27.75 |
| 9 x 6 | 18.50 |
| 12 x 9 | 9.25 |
| 18 x 10 | 5.55 |
| 25 x 10 | 4.00 |
Storage
Shelf life is 1 year when stored under cover, out of direct sunlight and protected from extremes of temperature.
Failure to comply with the recommended storage conditions may result in premature deterioration of the product or packaging. For specific storage advice consult KingKrete's Technical Services Department.
Health and safety
As with all chemical products, care should be taken during use and storage to avoid contact with eyes, mouth, skin and foodstuffs. Treat splashes to eyes and skin immediately. If accidentally ingested, seek medical attention. Reseal containers after use. Use in well ventilated areas and avoid inhalation.