KingMix 500CN®
State-of-the-art migratory corrosion-inhibiting admixture.
SpecWorld has the Spec Pack, CSI specification and drawings for registered specifiers.
Overview
KingMix 500CN is a state-of-the-art migratory corrosion-inhibiting admixture formulated to inhibit the corrosion of steel reinforcement in concrete. KingMix 500CN provides two levels of corrosion protection – inhibiting and waterproofing – making it a highly effective corrosion-inhibiting admixture.
Why use it
KingMix 500CN extends the service life of reinforced concrete by slowing the ingress of chlorides and moisture into the concrete and by forming a strong, durable protective film on the reinforcing steel for a second level of corrosion protection. This dual-mechanism system makes KingMix 500CN effective with all cement factors, as well as in cracked concrete where the elements that cause corrosion have direct access to the reinforcing steel.
How it works
KingMix 500CN functions by inhibiting corrosion at its most critical points. It lines the pores of the concrete matrix, waterproofing and slowing the rate at which chlorides and moisture enter the concrete and denying the corrosion process of its two most important components.
KingMix 500CN provides additional protection by migrating and adsorbing onto the reinforcing steel to form a corrosion-resistant protective film. This film dramatically slows the corrosion process by preventing chlorides from reacting with the reinforcing steel, and by depriving the corrosion process of moisture and oxygen, thus slowing the rate of corrosion once it begins.
Corrosion inhibiting systems
In order to control corrosion in steel-reinforced concrete, the ACI Building Code (ACI 318) requires certain design considerations, such as limiting the water-cementitious materials ratio, providing adequate concrete cover over reinforcing steel and limiting the initial chloride ion content of the concrete. Construction practices should be such that a dense, void-free concrete is obtained.
In addition to good concrete practice, KingKrete recommends a corrosion-inhibiting system that inhibits corrosion at multiple levels. The basis for this system is established through the use of KingMix 500CN, which restricts the ingress of chlorides and moisture and slows the rate of corrosion by forming a protective film on the reinforcing steel.
Non-chloride
KingMix 500CN will not initiate or promote corrosion of reinforcing steel embedded in concrete, prestressed concrete or concrete placed on galvanized steel floor and roof systems. Neither calcium chloride nor any chloride-based ingredients are used in the manufacture of KingMix 500CN.
Technical properties
Plastic properties
The plastic properties of concrete are not significantly affected by the use of KingMix 500CN.
Slump and temperature development
KingMix 500CN has no effect on slump or the temperature development profile of concrete.
Concrete-steel bond strength
Concrete-to-steel bond strength is not affected by KingMix 500CN.
Physical properties – test results (ASTM C1582)
| Control Specimen | KingMix 500CN | Difference | Requirements | Remarks | |
|---|---|---|---|---|---|
| Initial (Minutes) | 305 | 340 | 25 | ± 210 Minutes | Passed |
| Final (Minutes) | 410 | 474 | 64 | ± 210 Minutes | Passed |
| Control Specimen | KingMix 500CN | Difference | Requirements | Remarks | |
|---|---|---|---|---|---|
| 1 Day (MPa) | 23.5 | 26.4 | 112% | Min 80% | Passed |
| 3 Days (MPa) | 29.1 | 31.7 | 109% | Min 80% | Passed |
| 7 Days (MPa) | 36.7 | 39.5 | 108% | Min 80% | Passed |
| 28 Days (MPa) | 43.4 | 48.2 | 111% | Min 80% | Passed |
| 180 Days (MPa) | 46.2 | 49.8 | 108% | Min 80% | Passed |
| 365 Days (MPa) | 47.1 | 50.9 | 108% | Min 80% | Passed |
| Control Specimen | KingMix 500CN | Difference | Requirements | Remarks | |
|---|---|---|---|---|---|
| 1 Day (MPa) | 4.5 | 4.6 | 3% | Min 80% | Passed |
| 3 Days (MPa) | 4.6 | 4.8 | 4% | Min 80% | Passed |
| 7 Days (MPa) | 4.7 | 5.1 | 8% | Min 80% | Passed |
| 28 Days (MPa) | 5.4 | 6.0 | 11% | Min 80% | Passed |
| Control Specimen | KingMix 500CN | Difference | Requirements | Remarks | |
|---|---|---|---|---|---|
| Freeze / Thaw | 99.2 | 99.0 | 99.9 | RDF 80% | Passed |
| Control Specimen | KingMix 500CN | Difference | Requirements | Remarks | |
|---|---|---|---|---|---|
| Length Change | -0.023 | -0.022 | 0.001 | Max 0.01 | Passed |
Corrosion properties – test results (ASTM C1582)
| Potential mV(SSC) | Rp (Ohms) | Log (1/Rp) | Area (cm²) | Mean 1/Rp (µS/cm²) | SD 1/Rp (µS/cm²) | Log 1/Rp | Log SD | |
|---|---|---|---|---|---|---|---|---|
| 500CN-A | -545.2 | 8125 | 1.42 | 5.11 | 36.72 | 19.98 | 1.33 | 0.25 |
| 500CN-B | -525.3 | 5262 | 1.63 | 5.12 | ||||
| 500CN-C | -489.9 | 18001 | 1.15 | 5.11 | ||||
| 500CN-D | -495.2 | 9669 | 1.35 | 5.09 | ||||
| 500CN-E | -510.7 | 22565 | 0.95 | 5.11 | ||||
| 500CN-F | -455.2 | 3905 | 1.40 | 5.09 | ||||
| Average of 15 Control Specimen | -525.7 | 385.21 | 205.95 | 2.45 | 0.38 |
The above test results show that KingMix 500CN reduces the corrosion current (1/Rp) by a factor of twelve, so it meets the ASTM C1582 requirement of being 1/8 the value (49.3 µS/cm²) of the control specimens without inhibitor.
Standards and approvals
ASTM G109, ASTM C1582 and ASTM C494.
How to use
Directions for use
KingMix 500CN may be added with the concrete batch water. It should not be mixed with any other admixtures prior to being introduced into the concrete mixer. The use of this admixture does not require changes in normal batching procedures.
Dosage
KingMix 500CN is recommended for use at a dosage rate of 0.6 litre / m³ of concrete for all applications and corrosion environments. Dosed at 0.6 litre / m³, it is formulated to provide optimum corrosion protection of reinforced concrete structures in severe corrosive environments, and therefore provides excellent protection in less severe environments as well.
KingMix 500CN is formulated for use at a single dosage in order to eliminate the confusion and uncertainties related to determining the severity of the corrosive environment and predicting the chloride exposure of the structure.
Temperature precaution
Store at ambient temperatures above 1°C but not exceeding 58°C. Precautions should be taken to protect KingMix 500CN from freezing. If the product freezes, thaw and reconstitute by mild mechanical agitation. Do not use pressurized air for agitation.
Watchpoints
Trials must be carried out to ensure the mix design meets the specified performance criteria.
Quality and care
All products originating from KingKrete’s facility are manufactured under a management system independently certified to conform to the requirements of the quality standards ISO 9001, ISO 14001 and ISO 45001.
Limitations and notes
Field service, where provided, does not constitute supervisory responsibility. For additional information contact your local KingKrete representative. KingKrete Inc. reserves the right to have the true cause of any difficulty determined by accepted test methods.
Coverage, packaging and storage
Packaging
KingMix 500CN is available in 200 litre drums and in bulk if required.
Health and safety
KingMix 500CN is not a fire or health hazard. Spillages should be washed down immediately with cold water. For further information, refer to the material safety data sheet.