KingAdd 50HC®
Cement hydration controlling admixture.
SpecWorld has the Spec Pack, CSI specification and drawings for registered specifiers.
Overview
KingAdd 50HC is a liquid admixture formulated from selected polymers specially designed to retard the setting time by controlling the hydration process of Portland cement and other cementitious materials for a long time.
This effect can be used to keep concrete mixes workable for a long time starting from 3 hours till three days.
Where to use
- For wet type shotcrete.
- For long-distance concrete delivery.
- High-performance concrete.
- Concrete wash water stabilization.
- To avoid setting of concrete in transit mixers in case of an accident.
Why use it
- Reduces concrete waste in case of changing concrete casting schedule.
- Excellent retardation for a long time up to 3 days.
- Excellent slump retention for very long concrete deliveries.
- Saves transit mixer drums in case of accidents.
- Reduces the needed amount of water to clean the transit mixer.
- Chloride-free.
COMPATIBILITY
KingAdd 50HC is suitable to use with all types of Portland cement and cement replacement materials. KingAdd 50HC is compatible with other KINGKRETE admixtures used in the same concrete mix.
If more than one type of admixture is to be used, they must be dispensed into the mix separately.
Technical properties
Values @ 77°F (25°C)
| Colour | Brown liquid |
|---|---|
| Specific gravity | 1.06 ± 0.02 |
| pH | 6 - 9 |
| Chloride content | Chloride-free |
Standards and approvals
KingAdd 50HC complies with the requirements of Specification for Chemical Admixture for Concrete ASTM C494 as a Type B admixture.
How to use
Method of use
KingAdd 50HC should be added to the concrete with the mixing water to achieve optimum performance. Also it can be added directly to the drum of concrete mixers when unplanned changes in concrete casting schedule.
DOSAGE
The recommended dosage of KingAdd 50HC is between 2.5 to 123 fl oz/100 lb (163 to 7,995 ml/100 kg) of cementitious materials in the mix, including GGBFS, PFA or micro-silica. Actual dosage depends on the desired retardation.
Representative trials should first be conducted to determine the optimum dosage of KingAdd 50HC to meet the performance requirements by using the materials and conditions in actual use.
For traditional compliance with ASTM C494, the recommended dosage is between 2.5 to 10 fl oz/100 lb (163-650 ml/ 100 kg) of cementitious materials in the mix.
EFFECTS OF OVER DOSAGE
Overdosage of KingAdd 50HC will cause the following:
- Significant increase in retardation.
- Increase in workability.
Cleaning
Clean KingAdd 50HC with fresh cold water.
Coverage, packaging and storage
Packaging
KingAdd 50HC is available in 5 gal (19 litre) containers as well as 275 gal (1,041 litre) and 330 gal (1,249 litre) IBC totes. Bulk supply in tanker trucks is also available upon request.
Storage
Shelf life is 1 year when stored under cover, out of direct sunlight and protected from extremes of temperature.
Failure to comply with the recommended storage conditions may result in premature deterioration of the product or packaging. For specific storage advice consult KingKrete's Technical Services Department.
Health and safety
As with all chemical products, care should be taken during use and storage to avoid contact with eyes, mouth, skin and foodstuffs. Treat splashes to eyes
and skin immediately. If accidentally ingested, seek
medical attention. Reseal containers after use. Use in well ventilated areas and avoid inhalation.